The numbers refer to the explanatory diagrams.
Fully illustrated step by step
instructions are downloadable
on www.saniflo.co.uk
1
DESCRIPTION
The SANICUBIC 1 is a lifting station
designed to evacuate effluent from small
private dwellings.
Please comply with all the installation and
maintenance specifications set out in these
instructions, and especially the information
marked with the following signs:
"
" Failure to comply with this
information could entail safety
hazards for personnel,
"
" Information warning of the presence
of an electrical hazard,
"
" Instructions only for qualified
professional specialists,
"WARNING" Failure to comply with this
information could affect the normal
operation of the equipment.
Please contact our Customer service for
further information.
SANICUBIC 1 OPERATING
PRINCIPLE
SANICUBIC 1 contains 1 pump equipped
with a high performance maceration system.
The SANICUBIC 1tank is fitted with
2 dip tubes; one tube controls motor
operation, and the other one controls the
alarm system.
- Long pickup tube (normal operation):
as soon as the waste water level in the
tank reaches the triggering point in the
long tube, the pumping system starts up.
- Short pickup tube (inflow overload
operation): if the waste water level in the
tank reaches the upper point, a contact is
activated. This contact sets off a visual
alarm, the LED alarm on the control panel
switches to red.
The SANICUBIC 1 can be fitted with an
optional remote alarm unit (cabled) that
monitors the equipment's operational
status by producing visual signals.
2
LIST OF PARTS SUPPLIED
3
DIMENSIONS
4
TECHNICAL DATA
SANICUBIC 1
Type
Maximum discharge head
Voltage
Frequency
Volume
Maximum power input
Maximum current input
Electrical classification
Ave water temp for optimum performance 35°C
Maximum temperature (intermittent)
Protection index
Net weight (including accessories)
*Hot water drain cycles from dishwashers or washing machines
5
FIELD OF APPLICATION
Domestic household water waste.
6
PERFORMANCE CURVE
7
RATIO OF HEIGHT/LENGTH
FOR
DISCHARGE
8
INSTALLATION
The SANICUBIC 1 must be installed
in compliance with standard EN12056.
The equipment must be commissioned
and maintained by a qualified professional
specialist.
Please refer to installation standard
EN 12056.
REGULATIONS
8a
1- Attention: the space in which the
SANICUBIC 1 is to be installed
must be large enough to leave at least
600 mm of working room around and
above the unit to facilitate such
maintenance work as may be required.
There must be sufficient lighting, and it
must be sufficiently well ventilated and
protected from freezing.
2- Isolating valves (not supplied) must
be fitted on waste inlets (especially
the 110mm inlets) and on the
discharge to ensure that any
service/maintenance may be carried
out safely).
3- The discharge pipe must be fitted so as
to avoid all back flow from the drainage
system (see the examples in drawing
). Back flow can be avoided by
8g
installing an anti-back flow riser
reaching a high point above the
maximum back flow level.
Comment: In the absence of local
information to the contrary, the
maximum back flow level corresponds
to street level (roadway, pavements,
etc.). Continue the discharge pipework
after the anti-backflow riser, using a
larger diameter pipe.
4- If the Sanicubic 1 is installed in a space
such as a pit for example, we would
recommend the fitting of a bilge pump
in case of flooding.
5- The lifting station must be vented with
an outlet at roof level.
6- The lifting station must be fixed to the
floor (see paragraph
R350
CONNECTING THE DISCHARGE
8b
11 m
PIPE
220-240V
As each pump is fitted with a macerator
50 Hz
system, an ND50 mm discharge pipe can
32 l
be used.
1500 w
The discharge bend is at the centre of the
6 A
unit, at the back (cf.
I
to connect it to the riser pipe and fix it
D
in place with the collars.
70°C*
IP67
16 kg
Each pump in the SANICUBIC 1
unit is fitted with a check valve.
See paragraph
valves and back flow.
8c
make sure that the upper parts of the
plugholes on the sanitary equipment are
at least 250 mm above the lower inlets.
8d
Lower inlets (cf.
Upper inlet (cf.
• Cut off the end of the ND 50 inlet with a
saw
• Cut the sleeve
diameter: ND 40 or ND 50 (cf.
• Fix the sleeve
pipe, using the collars.
8e
Lower inlets (cf.
1- Remove the plug from the side inlet.
2- Fix the sleeve
3- Fully insert the ND 100/110 tube in the
Upper inlet (cf.
1- Cut off the upper end of the ND 100
2- Fix the sleeve
3- Fully insert the ND 100/110 tube in the
8f
1- VENT OF SANICUBIC 1
).
8h
2- VENTING THE ELECTRICAL
). Use the sleeve
8b
regarding control
8a
CONNECTING SANITARY
EQUIPMENT TO THE LOWER
INLETS
If you want to install a shower or a
bath at the same level as the
SANICUBIC 1, you must
CONNECTING THE INLETS ND 40/50
)
8d
1
)
8d
2
to suit the pipe
D
on the inlet and on the
D
CONNECTING THE ND 100/110 INLET
)
1
8e
in place using the
F
collar.
.
J
other end of the sleeve and fix it in
place using the other collar.
)
2
8e
inlet with a saw.
in place using the
F
collar
.
J
other end of the sleeve and fix it in
place using the other collar
CONNECTING THE VENT
One of the upper ND50 inlets must
be used for the vent. The vent pipe
must be fitted up to roof level.
Cut off the end of the one of the ND
50 inlets with a saw.
Then fix the sleeve
in place using
D
the collar
.
C
Fully insert the ND 50 tube in the
other end of the sleeve and fix it in
place using the other collar
WARNING: Do NOT fit air admittance
valve on the top of the air vent pipe.
The vent must be an open vent or the
unit will not operate.
CONTROL PANEL
Connect the 8/11 clear PVC tubing
supplied to the keyboard on the
Sanicubic 1. The other end of this
tubing must be located between 1m
and 2m above the device to avoid
water getting into the electrical into
the electrical control panel in the
event of surcharge of the incoming
waste.
Important: ensure that the tube is
not pinched or kinked
)
3
8d
.
J
.
J
.
C