Anti-Tip Bracket - Subzero ICBBI36FSPHRH Guide D’installation

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SITE PREPARATION

Anti-Tip Bracket

WARNING
To prevent the unit from tipping forward, the anti-tip
brackets must be installed.
The two anti-tip brackets must be installed exactly 24"
from the front of the opening to the back of the
(610)
brackets and a minimum of 4"
opening. This depth will increase to 26
inset installation based on
3
properly position the anti-tip brackets will prevent proper
engagement.
Use all anti-tip bracket hardware as instructed for wood or
concrete floors.
For wood or concrete floor applications,
IMPORTANT NOTE:
if the #12 screws do not hit a wall stud or wall plate, use the
#8 screws and #12 washers with the wall anchors.
In some installations the subflooring or
IMPORTANT NOTE:
finished floor may necessitate angling the screws used to
fasten the anti-tip brackets to the back wall.
ANTI-TIP HARDWARE
2
Anti-tip brackets
12
#12 x 2
1
/
" pan head screws
2
4
3
/
"–16 x 3
3
/
" wedge anchors
8
4
12
#12 flat washers
4
#8–18 x 1
1
/
" truss head screws
4
4
Nylon Zip-it
®
wall anchors
|
10
Sub-Zero Customer Care 800.222.7820
from the sides of the
(102)
3
/
"
for a flush
(665)
16
/
"
thick panels. Failure to
(19)
4
WOOD FLOOR APPLICATION
After properly locating the anti-tip brackets in the opening,
drill pilot holes
3
/
"
diameter maximum in the wall studs
(5)
16
or wall plate. Use the #12 screws and washers to secure the
brackets. Verify the screws penetrate through the flooring
material and into wall studs or wall plate a minimum of
. Refer to the illustration below.
(19)
CONCRETE FLOOR APPLICATION
After properly locating the anti-tip brackets in the opening,
drill pilot holes
3
/
"
diameter maximum in the wall studs
(5)
16
or wall plate. Drill
3
/
"
diameter holes into the concrete
(10)
8
a minimum of 1
1
/
"
deep. Use the #12 screws and
(38)
2
washers to secure the brackets to the wall, and use the
wedge anchors to secure the brackets to the floor. Verify
the screws penetrate wall studs or wall plate a minimum of
3
/
"
. Refer to the illustration below.
(19)
4
24"
(610)
4"
(102)
MIN
FINISHED
FLOORING
WALL PLATE
SUBFLOORING
WOOD FLOOR
Wood floor.
3
/
"
4
3
/
8
24"
(610)
4"
(102)
MIN
FINISHED
FINISHED
FLOORING
FLOORING
WALL PLATE
WALL PLATE
SUBFLOORING
SUBFLOORING
1
1
1
1
/
/
"
"
2
(38)
2
(38)
CONCRETE
CONCRETE
min
MIN
FLOOR
FLOOR
Concrete floor.
"

Publicidad

Tabla de contenido
loading

Tabla de contenido