Pump Priming; Run Test - ITT Goulds Pumps AquaBoost 1AB1 Instalación, Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Procedures

Pump Priming

Refer to your pump operation manual for instructions on pump priming. Ensure suction valve is open
before start up.

Run Test

WARNING
DO NOT APPLY POWER TO THE AQUABOOST CONTROLLER OR PUMP UNTIL ELECTRICAL
CONNECTIONS HAVE BEEN REVIEWED BY A QUALIFIED ELECTRICIAN AND MEET ALL AP-
PLICABLE NATIONAL, STATE AND LOCAL CODE REQUIREMENTS.
Instructions
1) Close discharge valve. Make sure the discharge valve is closed. Apply power to the
AquaBoost Controller.
2) Start the pump with the push button
3) Stop the pump after determining rotation by pushing the
4) If rotation is incorrect, turn off all power to the AquaBoost, open the motor conduit box and ex
change any two lead wires. Close the conduit box and reapply power.
Change Pressure
1) Start the pump with the push button
2) Then press the
3) The LED color changes to orange.
4) Now you could change the pressure with the
gauge on the pump discharge.
WARNING
DO NOT SET THE REQUIRED PRESSURE FOR MORE THAN 80 PSI SINCE THIS CAN EXCEDE
THE CAPABILITY OF YOUR PLUMBING SYSTEM AND TANK. SERIOUS PROPERTY DAMAGE
OR PERSONAL INJURY COULD RESULT.
5) If there is no change to the setting for more than 5 seconds, the AquaBoost Controller returns to
normal operation automatically, and the new required pressure is stored.
6) The pump can only be STARTED with the
are on the front plate of the AquaBoost Controller.
LED description
Green Solid – Motor is not running. The unit is stopped with the
Green Slow Flashing – Controller is active, but the motor has stopped.
Green Fast Flashing – Motor is running.
Red Solid – Error.
Red Flashing – Fatal error (AquaBoost Controller has to be disconnected from the power supply).
and
buttons together for more than 3 seconds.
on the front plate of the AquaBoost Controller.
.
on the front plate of the AquaBoost Controller.
and
buttons. The set pressure is read off a
button or STOPPED with the
9
button. Both buttons
button on the front plate.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Goulds pumps aquaboost 2ab1Goulds pumps aquaboost 3ab1

Tabla de contenido