Decrease in suction
strength
Troubleshooting
p
ossIble cause
Dirt recipient / Bag is full change bag. (see
Dirt recipient is not
properly attached
open vacuum inlet
exhaust line is clogged
Blocked hose
troubleshooting
c
orrectIVe actIon
page 24)
check clamps holding
dirt recipient, to make
sure they are tight, and
dirt recipient is aligned.
close all vacuum inlets
not in use.
Verify that no object is
blocking the exhaust.
plug the handle end of
the hose into the suction
inlet, thus reversing the
suction in the hose.
cover the gap around
the handle, to ensure
suitable suction strength,
and ensure contact with
inlet contacts to start the
unit. this should clear
the hose