Heat exchanger
Supply voltage
Cooling capacity
Q = 1 l/min at +25 °C
Max. delivery height
Max. coolant pump capacity
Max. coolant outlet pressure/coolant pump
pressure
Coolant pump type
Coolant container capacity
Coolant
Sound level
Protection type
Dimensions (lxwxh)
Weight
Tab. 1
CR1000/CR1250 cooling unit
Ambient temperature
Relative humidity
Tab. 2
Ambient conditions during operation
Storage in a closed environment, ambient temperature
Ambient temperature for shipment
Relative humidity
Tab. 3
Ambient conditions for transport and storage
3.2 Abbreviations
S.W.
Tab. 4
Abbreviations
Unit of measurement in drawings or diagrams
Tab. 5
Dimensions
EN - 6
CR1000
2-row
115/230VAC 50/60Hz
1000 W with H
O
2
750 W with BTC-15
Approx. 35 m 230V
7.0 l/min
3.5 bar
Centrifugal pump
6.0 l
from the BTC range
approx. 67 db(A)
IP 23 (suitable for indoor use only)
490x250x410 mm
14.9 kg
-10°C to +40°C
Up to 90% at 20°C
-10°C to +40°C
-25°C to +55°C
Up to 90% at 20°C
Flow control (water flow switch)
Millimetres [mm]
CR1000/CR1250
CR1250
3-row
1250 W with H
O
2
1050 W with BTC-15
690x250x340 mm
16.7 kg