2. Installation

2.4 Daisy-Chaining

Warning! The total length of daisy-chain cabling from the master KVM switch to the last KVM switch in a daisy-chain installation
(regardless of the number of levels) must not exceed 98 ft. (30 m). If the total length of daisy-chain cabling exceeds 98 ft. (30 m),
the installation will not function properly. Note: Previous versions of NetController KVM Switches may not support this distance. If you
experience problems daisy-chaining at this distance, you may need to upgrade the firmware of your unit(s).
To increase the number of connected computers up to 256*, up to 16 levels of NetController KVM Switches can be daisy-chained together. The
diagram and steps below describe how to set up a daisy-chain installation.
*When (16) 16-Port KVM switches are daisy-chained together.
Step 1: Connect the external power supply (B042-Series KVMs) or power cord (B040-Series KVMs) to the Master KVM switch, then plug it into a
Tripp Lite Surge Protector, PDU or Uninterruptible Power Supply (UPS).
Note: B040-Series Console KVM Switches can only occupy the first position in a daisy-chain.
Step 2: B042-Series KVM Switches Only: Connect a USB or PS/2 keyboard, mouse, and a monitor to the console ports on the back of the Master
KVM switch.
Note: Any combination of mouse and keyboard will work; PS/2 keyboard and mouse, USB keyboard and mouse, PS/2 keyboard and USB mouse, USB keyboard
and PS/2 mouse.
Step 3: B040-Series Console KVM Switches Only: Connect an external USB mouse or keyboard, and an external monitor to the corresponding
external console ports on the back of the Master Console KVM switch. You can also add remote access to the KVM switch by connecting
a B051-000 IP Remote Access unit to the external console ports on the back of the unit. (See the B051-000 manual for details on
installation.)
Note: If you are not using the External VGA Monitor port, you must connect the External VGA Port Terminator to it for the unit to function properly.
Step 4: Using the included 8 in. Daisy-Chain Cable, or a P781-Series Daisy-Chain Cable (sold separately), connect the Daisy-Chain Out port of the
Master KVM switch to the Daisy-Chain In port of the second-level B042-Series KVM Switch.
Note: The maximum distance between any two daisy-chained KVM switches is 98 ft (30 m)*.
Step 5: Connect the external power supply to the second-level B042-Series KVM Switch and then plug it into a Tripp Lite Surge Protector, PDU or
Uninterruptible Power Supply (UPS). Repeat steps 4 and 5 for any additional KVM switches you are adding, with no more than 16 KVM
switches in the entire installation.
Step 6: After you have daisy-chained all of the KVM switches, connect the Daisy-Chain Terminator that came with your B042-Series KVM Switch to
the Daisy-Chain Out port of the last KVM in the installation.
Step 7: Using Tripp Lite P780-Series USB/PS2 Combo KVM Cable Kits, connect a computer to an available computer port on the installation. Repeat
this step for each additional computer you are connecting.
Step 8: Power on the connected computers.
* Previous versions of NetController KVM Switches may not support these distances. If you experience problems when daisy-chaining within the max distance requirements,
you may need to upgrade the firmware of your unit. (See page 10 for details on performing a firmware upgrade.)
P781-series daisy-chain cables
Warning! Total daisy-chain cabling distance
from the master KVM switch to the last KVM
switch must not exceed 98 ft. (30 m).
.
Host computer not needed at any other time.
Daisy-chain up to 16 levels
6
P780-series
cable kit
P780-series
cables
BANK 16