Set-Up
Gas and Oil Fill-Up
Service the engine with gasoline and oil as instructed in the engine
manual packed with your log splitter. Read the instructions carefully.
WARNING!
gasoline. Gasoline is extremely flammable and the
vapors are explosive. Never fuel the machine
indoors or while the engine is hot or running.
NOTE: Your log splitter may be shipped with motor oil in the
engine. You MUST check the oil level before operating. Be careful
not to overfill. Gasoline can be added to the engine when the log
splitter is in either the horizontal or vertical position. However, it
may be easier when the splitter is in the vertical position.
Tire Pressure
The max recommended operating pressure is 30 psi. Do
not -- under any circumstances -- exceed the manufacturer's
recommended psi. Maintain equal pressure on all tires.
WARNING!
may cause tire/rim assembly to burst with force
sufficient to cause serious injury.
Preparing the Log Splitter
1.
Lubricate the beam area (where the splitting wedge will
slide) with engine oil. Do not use grease.
2.
Remove the dipstick located in front of the engine and on top
of the reservoir tank. See Figure 3-9.
NOTE: The log splitter is filled to the proper operating level
from the manufacturer with Shell Tellus® S2 M 32 Hydraulic
Fluid. However, you MUST check the fluid level before
operating. If not filled, proceed with the following steps:
WARNING!
drawn into the cylinder and hoses. Make certain to
refill the reservoir to prevent damage to the
hydraulic pump.
10
S
2— A
ection
SSembly
Use extreme care when handling
Excessive pressure when seating beads
Dipstick
Reservoir
Tank
Figure 3-9
Much of the original fluid has been
& S
-U
et
p
3.
Check the fluid level using the dipstick. See Figure 3-9. Do
not overfill.
NOTE: Approved fluids include Shell Tellus® S2 M
32 Hydraulic Fluid, Dexron® III/Mercon® automatic
transmission fluid, Pro-Select™ AW-32 Hydraulic Oil or
10WAW-ISO viscosity grade 32 hydraulic oil. It is not
recommended that fluids be mixed, to top off the reservoir
tank during initial set-up use Shell Tellus® S2 M 32 Hydraulic
Fluid only.
4.
Replace the dipstick securely, tightening it until the top of
the threads are flush with top of the pipe.
5.
Disconnect the spark plug and prime the pump by pulling the
recoil starter as far as it will go. Repeat approximately 10 times.
6.
Reconnect the spark plug wire and start the engine
following instructions in the Engine Operator's Manual.
7.
Use the control handle to engage the wedge to the farthest
extended position. Then retract the wedge.
8.
Refill the tank as indicated on the dipstick if necessary.
NOTE: Failure to refill the tank will void the log splitter's
warranty.
9.
Extend and retract the wedge 12 complete cycles to
remove any trapped air in the system (the system is "self-
bleeding").
10.
Refill the reservoir within the range marked on the dipstick
if necessary.
NOTE: Some fluid may overflow from the vent plug as the
system builds heat and the fluid expands and seeks a
balanced level.