Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Cedar Ridge
h e a r t h
VENT-FREE GAS WALL HEATER
OWNER'S OPERATION AND
INSTALLATION MANUAL
INFRARED MODEL
MD3TPF
PFS
®
US
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable va-
pors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST,
Monday through Friday or email customerservice@usaprocom.com
®

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Resumen de contenidos para Cedar Ridge MD3TPF

  • Página 1 Cedar Ridge ® h e a r t h VENT-FREE GAS WALL HEATER OWNER’S OPERATION AND INSTALLATION MANUAL INFRARED MODEL MD3TPF ® WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Página 2: Tabla De Contenido

    TABLE OF CONTENTS Safety ............3 Operation ..........18 Specifications ..........4 Inspecting Burners........21 Qualified Installing Agency ......5 Care And Maintenance ......22 Product Features ........5 Troubleshooting ........23 Local Codes..........5 Parts ............26 Preparing For Installation ......6 Replacement Parts ........
  • Página 3: Safety

    SAFETY Natural And Propane/LP Gas: Natural and IMPORTANT: Read this owner’s Propane/LP gas are odorless. An odor-making manual carefully and completely agent is added to the gas. The odor helps you before trying to assemble, op- detect a gas leak. However, the odor added to erate, or service this heater.
  • Página 4: Specifications

    100 lbs. capacity. keeps shutting off, have it serviced. 6. Do not run heater: • Where flammable liquids or vapors are used or stored. • Under dusty conditions. SPECIFICATIONS MODEL MD3TPF Gas Type Natural Propane/LP BTU (available) 20,000 18,000 Manifold Pressure 6"...
  • Página 5: Qualified Installing Agency

    QUALIFIED INSTALLING AGENCY Only a qualified agency should install and a) Installing, testing, or replacing gas piping replace gas piping, gas utilization equipment or accessories, and repair and equipment ser- b) Connecting, installing, testing, repairing, vicing. The term “qualified agency” means any or servicing equipment;...
  • Página 6: Preparing For Installation

    PREPARING FOR INSTALLATION Before beginning assembly or operation of the product, make sure all parts are present. Compare parts with package contents list. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement parts. UNPACKING 1.
  • Página 7: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION heat loss in homes. Home owners weather WARNING: This heater shall strip and caulk around windows and doors not be installed in a confined space to keep the cold air out and the warm air in. During heating months, home owners want or unusually tight construction their homes as airtight as possible.
  • Página 8 AIR FOR COMBUSTION AND VENTILATION DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have Example: a confined or unconfined space. Gas water heater __________ Btu/Hr 30,000 Vent-free heater + _________ Btu/Hr...
  • Página 9 AIR FOR COMBUSTION AND VENTILATION WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes.
  • Página 10: Installation

    INSTALLATION IMPORTANT: Vent-free heaters add moisture NOTICE: This heater is intended to the air. Although this is beneficial, installing for use as supplemental heat. heater in rooms without enough ventilation air Use this heater along with your may cause mildew to form too much moisture. primary heating system.
  • Página 11: Locating Heater

    INSTALLATION LOCATING HEATER This heater is designed to be mounted on a 1. Where there is easy access for operation, wall. For convenience and efficiency, install inspection, and service. heater: 2. In the coldest part of room. INSTALLING THERMOSTAT SENSING BULB (OPTIONAL) 1.
  • Página 12 INSTALLATION Methods For Attaching Mounting Attaching Mounting Bracket To Wall Bracket To Wall Note: Wall anchors, mounting screws, and Use only the last hole on each end of mounting spacers are in hardware package. The hard- bracket to attach bracket to wall. Attach mount- ware package is provided with heater.
  • Página 13 INSTALLATION INSTALLING BASE FEET Placing Heater On Mounting Bracket Before installing heater to the base, please 1. Locate two horizontal slots on back panel make sure you have the following items: of heater (see Figure 10). (2) Base Feet 2. Place heater onto mounting bracket. Slide (4) Sheet Metal Screws horizontal slots onto stand-out tabs on Installation Procedure:...
  • Página 14 INSTALLATION For changing from propane to natural gas supply: 1. Remove top screw from cover plate lo- cated on back of heater (see Figure 12). Fuel Rotate to expose fuel selection device. Selector Knob 2. For NATURAL GAS, press knob using a flat screwdriver with a blade with thick- ness of a quarter and turn knob clockwise until the knob locks into the NG...
  • Página 15: Connecting To Gas Supply

    INSTALLATION CONNECTING TO GAS SUPPLY CAUTION: For natural gas, WARNING: A qualified ser- check your gas line pressure vice technician must connect before connecting heater to gas heater to gas supply. Follow all line. Gas line pressure must be local codes. no greater than 10.5"...
  • Página 16 INSTALLATION For propane/LP gas, the installer must supply Typical Inlet Pipe Diameters an external regulator. The external regulator Use 3/8" black iron pipe or greater. Installa- will reduce incoming gas pressure. You must tion must include an equipment shutoff valve, reduce incoming gas pressure to between 11"...
  • Página 17 INSTALLATION CHECKING GAS CONNECTIONS WARNING: Never use an WARNING: Test all gas piping open flame to check for a leak. and connections for leaks after Apply a mixture of liquid soap installing or servicing. Correct and water to all joints. If bubbles all leaks at once.
  • Página 18: Operation

    OPERATION PRESSURE TESTING HEATER GAS CONNECTIONS 1. Open equipment shutoff valve (see Figure 17, page 17). Apply a noncorrosive leak 15, page 17). detection fluid to all joints. Bubbles forming show a leak. 2. For natural gas open main gas valve lo- cated on or near gas meter.
  • Página 19: To Turn Off Gas To Appliance

    OPERATION bleed from the gas system. If pilot does 8. Turn control knob counterclockwise not stay lit, refer to Troubleshooting, pages to desired heating level. The main burner 23 though 25. Also contact a qualified should light. Set control knob to any heat service technician or gas supplier for level between 1 and 5.
  • Página 20: Fan Operation

    OPERATION MANUAL LIGHTING PROCEDURE Ignitor 1. Follow steps 1 through 5 under Lighting Natural Electrode Thermocouple Instructions, page 18. 2. With control knob in PILOT position, strike Burner Propane/LP match, and hold near pilot. Press in control Gas Burner knob; pilot should light. 3.
  • Página 21: Inspecting Burners

    INSPECTING BURNERS IMPORTANT: Owner’s should check pilot flame pattern and burner flame pattern often. Incorrect flame patterns indicate the need for cleaning (see Care and Maintenance, page 22) or service. WARNING: Only a qualified service person should service and repair heater. This includes maintenance requiring replacement or alteration of components.
  • Página 22: Care And Maintenance

    CARE AND MAINTENANCE WARNING: Turn off heater and let cool before servicing. CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service techni- cian.
  • Página 23: Troubleshooting

    TROUBLESHOOTING WARNING: If you smell gas: • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
  • Página 24 TROUBLESHOOTING Problem Possible Cause Corrective Action ODS/pilot lights but flame 1. Control knob is not fully 1. Press in control knob fully. goes out when control pressed in. knob is released. 2. Control knob is not pressed 2. After ODS/pilot lights, keep in long enough.
  • Página 25 TROUBLESHOOTING Problem Possible Cause Corrective Action Slight smoke or odor 1. Residues from manufactur- 1. Problem will stop after a few during initial operation. ing process. hours of operation. Heater produces a whis- 1. Turning control knob to high 1. Turn control knob to low (1) tling noise when burner (5) position when burner is position and let warm up for...
  • Página 26: Parts

    PARTS MODEL MD3TPF www.usaprocom.com 200033-01B...
  • Página 27 PARTS MODEL MD3TPF This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 28 of this manual. ITEM PART # DESCRIPTION QTY. MEL301-01A-CG Front Cover NDD0308-800 ODS Pilot ND0803-8...
  • Página 28: Replacement Parts

    REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. • Model and serial number of your heater If they can’t supply original replacement •...
  • Página 29: Service Hints

    SERVICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • propane/LP gas supply might be low (propane/LP units only) You may feel your gas pressure is too low. If so, contact your local gas supplier. TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting.
  • Página 30 NOTES ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ www.usaprocom.com 200033-01B...
  • Página 31 NOTES ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ www.usaprocom.com 200033-01B...
  • Página 32: Warranty

    WARRANTY KEEP THIS WARRANTY Model _______________________________ Serial No. ____________________________ Date Purchased _______________________ Keep receipt for warranty verification. IMPORTANT: We urge you to fill your warranty registration card within TEN(10) days of date of installation, complete with the entire serial number which can be found on the rating plate. Retain this portion of the card for your record.
  • Página 33: Calentador De Gas De Pared Sin Ventilas

    Cedar Ridge ® h e a r t h CALENTADOR DE GAS DE PARED SIN VENTILAS MANUAL DE FUNCIONAMIENTO E INSTALACIÓN DEL PROPIETARIO INFRARROJO MODELO MD3TPF ® ADVERTENCIA: Si la información contenida en este manual no se sigue al pie de la letra, se pueden producir un incendio o una explosión que podrían ocasionar daños...
  • Página 34 TABLA DE CONTENIDOS Seguridad ..........35 Instalación ..........42 Especificaciones ........37 Funcionamiento ........51 Agencia De Instalación Calificada ... 37 Inspección de los Quemadores ....54 Características Del Producto ....37 Cuidado y mantenimiento ......55 Normas Locales........38 Solución de problemas ......
  • Página 35: Seguridad

    SEGURIDAD nando correctamente. ¡Respire aire fresco IMPORTANTE: Lea este manual del inmediatamente! Haga que le den servicio propietario cuidadosa y completa- al calentador. El monóxido de carbono afecta mente antes de intentar ensamblar, más algunas personas que a otras. Las más operar o dar servicio a este calen- afectadas son mujeres embarazadas, perso- nas con enfermedades del corazón, de los...
  • Página 36 SEGURIDAD 5. Si el calentador se apaga, no lo vuelva ADVERTENCIA: Este calen- a encender hasta que se le haya pro- tador alcanza temperaturas muy porcionado aire fresco del exterior. Si el altas cuando el calentador está calentador continua apagando se debera ser revisado por personal calificado.
  • Página 37: Especificaciones

    ESPECIFICACIONES MODELO MD3TPF Tipo de gas Natural Propano/LP BTU (disponible) 20,000 18,000 Presión del tubo múltiple 6" de c.a. 10" de c.a. Presión de entrada de gas Máxima 10.5" Máxima 14" (pulg. de c.a.) Mínima 7" Mínima 11" Encendido Piezoeléctrico Electric Piezo Dimensiones del calentador (alto x ancho x profundidad) •...
  • Página 38: Normas Locales

    NORMAS LOCALES Instale y use el calentador con cuidado. Siga Estado de Massachusetts: La instalación todas las normas locales. A falta de normas loca- la debe realizar un plomero o un instalador les, utilice la última edición del Código Nacional de gas con licencia para ejercer en el esta- de Gas Combustible, ANSI Z223.1/NFPA 54*.
  • Página 39: Aire Para Combustión Y Ventilación

    AIRE PARA COMBUSTIÓN Y VENTILACIÓN calor en las casas. Los propietarios de casas ADVERTENCIA: Este calen- aislan y sellan alrededor de las ventanas y tador no debe instalarse en un puertas para mantener el aire frío afuera y el espacio confinado ni en una cons- aire caliente adentro.
  • Página 40: Determinación Del Flujo De Aire Fresco Para Ubicar El Calentador

    AIRE PARA COMBUSTIÓN Y VENTILACIÓN Espacio confinado y no confinado El Código Nacional de Gas Combustible, instalados en ese espacio. Las habitaciones ANSI Z223.1/NFPA 54, define el espacio con- que se comunican directamente con el espa- finado como aquél cuyo volumen es menor de cio en el que están instalados los aparatos*, 4.8 m por kw (50 pies...
  • Página 41: Aire Para Ventilación

    AIRE PARA COMBUSTIÓN Y VENTILACIÓN ADVERTENCIA: Si el área en la que se va a operar el calentador no cumple los requisitos de volumen de aire de combustión para interiores, se debe proporcionar aire para combustión y ventilación mediante uno de los métodos descritos en el Código Nacional de Gas Combustible, ANSI Z223.1/NFPA 54, el Código Internacional de Gas Combustible o los códigos locales aplicables.
  • Página 42: Instalación

    INSTALACIÓN AVISO: Este calentador está PRECAUCIÓN: Este calen- diseñado para utilizarse como tador crea corrientes de aire calefacción adicional. Use este caliente. Estas corrientes mue- calentador junto con su sistema ven el calor hacia la superficie de calefacción principal. No de las paredes próximas al instale este calentador como calentador.
  • Página 43: Ubicación Del Calentador

    INSTALACIÓN DISTANCIA DE SEPARACIÓN DE COMBUSTIBLES Siga con atención las siguientes instruc- TECHO ciones. Este calentador es una unidad de montaje en la pared diseñada para apoyarse 15.2 cm (6") Un mínimo directamente sobre el suelo o una base de Distancias de 91.5 cm mínimas...
  • Página 44: Colocación Del Calentador En La Pared

    INSTALACIÓN INSTRUCCIONES PARA LAS BATERÍAS Desatornille la tapa del encendedor e instale PRECAUCIÓN: No mezcle una batería AAA con el ánodo (+) apuntando baterías nuevas con usadas. No hacia afuera. Vuelva a colocar la tapa. mezcle baterías alcalinas, están- dar (carbono - zinc) o recargables (níquel - cadmio).
  • Página 45: Instalación Del Soporte De Montaje A La Pared

    INSTALACIÓN Método de fijación a anclajes de pared 2. Marque la ubicación de los tornillos en la Para fijar el soporte de montaje en paredes pared (consulte la figura 7). huecas (el área entre las vigas) o en paredes Nota: Marque únicamente el último orificio sólidas (de concreto o mampostería) de cada extremo del soporte de montaje.
  • Página 46: Procedimiento De Instalación

    INSTALACIÓN INSTALACIÓN DE LAS PATAS BASE Colocación del calentador en el soporte de montaje Antes de instalar el calentador a la base, 1. Localice las dos ranuras horizontales en asegúrese de tener los siguientes artículos: el panel posterior del calentador (consulte (2) patas base la figura 10).
  • Página 47 INSTALACIÓN El cambio del selector de configuración dis- regulador. Instale la tubería de gas en la tinto del tipo de combustible especificado en entrada del regulador de gas natural. Uti- el momento de instalación podría dañar este lice sellador de roscado para evitar fugas. dispositivo y dejarlo inoperable.
  • Página 48: Conexión Al Suministro De Gas

    INSTALACIÓN CONEXIÓN AL SUMINISTRO DE GAS ADVERTENCIA: Una per- PRECAUCIÓN: Para gas sona de servicio capacitada propano/LP, nunca conecte el debe conectar el calentador al calentador directamente al sumi- suministro de gas. Siga todas nistro de gas propano/LP. Este las normas locales. calentador requiere un regulador externo (no se incluye).
  • Página 49 INSTALACIÓN • regulador externo para gas propano/LP válvula de cierre del equipo es para abrir o (proporcionado por el técnico capacitado cerrar el suministro de gas al aparato. que realiza la instalación) Para gas propano/LP, aplique una pequeña • tubería (consulte los códigos locales), cantidad de sellador de tubería a las roscas •...
  • Página 50 INSTALACIÓN REVISIÓN DE LAS CONEXIONES DE GAS ADVERTENCIA: Nunca use una ADVERTENCIA: Después llama al descubierto para verificar de instalar el calentador o de si hay fugas. Aplique líquido no darle servicio, pruebe todas las corrosivo para detectar fugas en conexiones y tubos de gas de la todas las uniones.
  • Página 51: Comprobación De La Presión De Las Conexiones De Gas Del Calentador

    COMPROBACIÓN DE LA PRESIÓN DE LAS CONEXIONES DE GAS DEL CALENTADOR 1. Abra la válvula de cierre del equipo (con- la página 50). Aplique en todas las unio- sulte la figura 16, en la página 50). nes algún líquido de detección de fugas que no sea corrosivo.
  • Página 52 FUNCIONAMIENTO 5. Gire la perilla de control en sentido con- un (1) minuto antes de encender el piloto trario de las manecillas del reloj nuevamente. hasta la posición PILOT (piloto). Presione 8. Gire la perilla de control en sentido con- la perilla de control durante cinco (5) se- trario de las manecillas del reloj gundos (consulte la Figura 19).
  • Página 53: Cómo Cerrar El Suministro De Gas Al Aparato

    FUNCIONAMIENTO FUNCIONAMIENTO DEL CONTROL CON TERMOSTATO El control termostático que se usa en es- la habitación puede ser mayor que la estable- tos modelos es distinto de los termostatos cida. Si esto ocurre, el quemador se apagará. convencionales. Los termostatos conven- El quemador volverá...
  • Página 54: Inspección De Los Quemadores

    INSPECCIÓN DE LOS QUEMADORES IMPORTANTE: El propietario debe revisar frecuentemente los patrones de la llama del piloto y de la llama del quemador. Patrones de llama incorrectos indican la necesidad de limpieza o servicio de mantenimiento (consulte Cuidado y mantenimiento, página 55). ADVERTENCIA: Sólo una persona de servicio capacitada debe repararlo o darle servicio.
  • Página 55: Cuidado Y Mantenimiento

    CUIDADO Y MANTENIMIENTO ADVERTENCIA: Apague el calentador y deje que se enfríe antes de darle mantenimiento. PRECAUCIÓN: Debe mantener limpias las áreas de control, el quemador y las vias de circulación de aire del calentador. Inspec- cione estas áreas del calentador antes de cada uso. Haga que una persona de servicio calificada inspeccione el calentador una vez al año.
  • Página 56: Solución De Problemas

    CUIDADO Y MANTENIMIENTO ODS/PILOTO Utilice una aspiradora, aire comprimido o Quemador de gas natural Quemador un cepillo pequeño, de cerdas suaves para de gas limpiarlos. propano/LP Si la llama del piloto tiene la punta amarilla, indica la presencia de polvo y suciedad en el ensamble del piloto.
  • Página 57: Acción Correctiva

    SOLUCIÓN DE PROBLEMAS Problema Causa Posible Acción correctiva Cuando se presiona el 1. Electrodo de encendido 1. Remplace el electrodo del botón del encendedor, no está mal colocado. Electro- encendedor. hay chispa en el piloto/ do de encendido está roto. ODS.
  • Página 58: Causa Posible

    SOLUCIÓN DE PROBLEMAS Problema Causa Posible Acción correctiva El piloto/ODS se en- 1. La perilla de control no está 1. Presione la perilla de control ciende pero la llama se presionada completamente. completamente. extingue cuando la perilla 2. La perilla de control no se 2.
  • Página 59 SOLUCIÓN DE PROBLEMAS Problema Causa Posible Acción correctiva Llamas amarillas alta 1. No hay suficiente aire. 1. Revise el quemador en busca durante la combustión de polvo y residuos. Si los hay, en el quemador. limpie el quemador (consulte Cuidado y mantenimiento, en la página 55).
  • Página 60 SOLUCIÓN DE PROBLEMAS Problema Causa Posible Acción correctiva El calentador produce 1. En el calentador se están 1. Abra la ventana para ventilar olores no deseados. quemado vapores prove- la habitación. Deje de utilizar nientes de pintura, fijador los productos que ocasionan para el cabello, pegamen- el olor mientras el calentador tos, productos de limpieza,...
  • Página 61: Piezas De Repuesto

    PIEZAS DE REPUESTO Nota: use sólo piezas de repuesto originales. Esto protegerá la cobertura de su garantía para partes remplazadas bajo la garantía. PIEZAS CON GARANTÍA Comuníquese con los distribuidores autoriza- • su nombre, dos de este producto. Si no pueden proporcio- •...
  • Página 62: Piezas

    PIEZAS MODELO MD3TPF www.usaprocom.com 200033-01B...
  • Página 63 PIEZAS MODELO MD3TPF Esta lista contiene las piezas remplazables utilizadas en el calentador. Al hacer un pedido de piezas, siga las instrucciones listadas en Piezas de repuesto en la página 61 de este manual. Artículo Pieza # Descripción Cant. MEL210-01A-CG Cubierta fronta...
  • Página 64: Garantía

    GARANTÍA GUARDE ESTA GARANTÍA Modelo __________________________________ Número de serie __________________________ Fecha de compra _________________________ Conserve su recibo para la verificación de la garantía. IMPORTANTE: Llene la tarjeta de registro de garantía dentro de los 10 diez días de la fecha de instalación, complete con el número de serie completo que puede encontrarse en la placa de calificación.

Tabla de contenido