bleed from the gas system. If pilot does
not stay lit, refer to Troubleshooting, pages
23 though 25. Also contact a qualified
service technician or gas supplier for
repairs. Until repairs are made, light pilot
with match.
• If control knob does not pop up when
released, contact a qualified service
technician or gas supplier for repairs.
6. With control knob pressed in, push
down and rele ase ignitor button. This
will light pilot. The pilot is attached to
the front of burner. The pilot can be
seen through the grill. If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 23 though 25.
Also contact a qualified service technician
or gas supplier for repairs. Until repairs
are made, light pilot with match. To light
pilot with match, see Manual Lighting
Procedure, page 20.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. If control
knob does not pop up when released,
contact a qualified service technician or
gas supplier for repairs.
Note: If pilot goes out, repeat steps 2
through 6. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
The thermostatic control used on this model
differs from standard thermostats. Standard
thermostats simply turn the burner on and off.
The thermostat used on this heater senses
the room temperature. At times the room may
Shutting Off Heater
Turn control knob clockwise
OFF position.
200033-01B
OPERATION
THERMOSTAT CONTROL OPERATION

TO TURN OFF GAS TO APPLIANCE

to the
www.usaprocom.com
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between 1 and 5.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas type is
NG, make sure NG pilot burner ig-
nites. If input gas type is LP, make
sure LP pilot burner ignites.
Control Knob
Figure 20 - Burner Patterns
exceed the set temperature. If so, the burner
will shut off. The burner will cycle back on
when room temperature drops below the set
temperature. The control knob can be set to
any comfort level between 1 and 5.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise
PILOT position.
Burners
to the