Battery Replacement; Cleaning And Disinfection - Self-Diagnostics SD-T Flex 120 Manual Del Usuario

Termómetro digital flexible instantáneo
Ocultar thumbs Ver también para SD-T Flex 120:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

°C / °F SWITCHABLE
Temperature readings are available in both Fahrenheit or Celsius scales (°C / °F; located in the upper
right corner of the LCD screen). With the unit off, press and hold the On/Off Button for approxi-
mately 4 seconds to change the current setting.
DIRECTIONS
1. Press the On/Off Button next to LCD display. A tone will sound as the screen shows
followed by the last recorded temperature. After showing the self-test temperature, the ther-
mometer is now ready for testing.
If the measured temperature is less than 32°C or 90°F, the LCD will display Lo, if the measured
temperature is higher than 42.9°C or 109.9°F, the LCD will display Hi.
2. Position thermometer in desired location (mouth, rectum or armpit).
a) Oral Use: Place thermometer under tongue as indicated by » √ « position
shown in Figure 2. Close your mouth and breathe evenly through the nose
to prevent the measurement from being influenced by inhaled/exhaled
air. A normal temperature reading is between 35.7°C and 37.3°C (96.3°F and 99.1°F).
b) Rectal Use: Lubricate silver probe tip with petroleum jelly for easy insertion. Gently insert
sensor approximately 1cm (less than 1/2") into rectum. A normal temperature reading is
between 36.2°C and 37.7°C (97.2°F and 99.9°F).
c) Armpit Use: Wipe armpit dry. Place probe in armpit and keep arm pressed firmly at side.
From a medical viewpoint, this method will always provide inaccurate readings, and should
not be used if precise measurements are required. Normal temperature between 35.2°C and
36.7°C (95.4°F and 98.1°F).
3. The degree sign will flash throughout the testing process. When the flashing stops an alarm will beep for
approximately 10 seconds. The measured reading will appear on the LCD screen simultaneously. The
minimum measurement time until the signaling tone (beep) must be maintained without excep-
tion. The measurement continues even after the buzzer notification. The displayed temperature
will not change when thermometer is removed from its testing position.
Normally the buzzes are » Bi-Bi-Bi-Bi «; Alarm beeps more rapidly when temperature reaches
37.8°C (100°F) or higher, and the buzzes are » Bi-Bi-Bi------Bi-Bi-Bi------Bi-Bi-Bi «
4. To prolong battery life, press the On/Off Button to turn unit off after testing is complete. If no
action is taken, the unit will automatically shut off after around 10 minutes.
5. Store the thermometer in its protective case.

BATTERY REPLACEMENT

1. Replace battery when »   « appears in the lower right corner of LCD display.
2. Pull battery cover off as shown in Figure 3.
3. Gently pull out plastic circuit board with battery chamber approximately 1cm (slightly less
than 1/2"). (See Figure 4)
4. Use a pointed object such as a pen to remove the old battery. Discard the battery lawfully.
Replace with new 1.5V DC button type LR41 or SR41, UCC392 or equivalent.
Be sure battery is installed with » + « polarity facing up. (See Figure 5)
5. Slide the battery chamber back into place and attach cover.
Figure 3

CLEANING AND DISINFECTION

Wipe the thermometer with a soft clean cloth.
For stubborn stains, wipe the thermometer with a cloth that has been dampened with water or a
neutral detergent solution and then wring thoroughly. Finish by wiping with a soft dry cloth.
Observe the following to prevent damage to the thermometer.
• Do not use benzene, thinner, gasoline or other strong solvents to clean the thermometer.
• Do not soak the sensing section in alcohol for long periods of time or attempt to sterilize it using
hot water (water at a temperature of 50°C (122°F) or higher).
• Do not use ultrasonic washing to clean the thermometer.
LIMITED WARRANTY
The thermometer is guaranteed for one year from the date of purchase. If the thermometer does
not function properly due to defective components or poor workmanship, we will repair or replace
it free of charge. All components are covered by this warranty excluding the battery. The warranty
does not cover damages to your thermometer due to improper handling. To obtain warranty service,
an original or copy of the sales receipt from the original retailer is required.
The product is in compliance with the requirements of MDD 93/42/EEC,
"0197" is the identification number of notify body.
0197
Disposal of this product and used batteries should be carried out in accordance with the
national regulations forthe disposal of electronic products.
Hangzhou Sejoy Electronics & Instruments Co., Ltd.
Building 2, No.202, Zhenzhong Road, West Lake Economy & Technology Zone 310030 Hangzhou China
EC REP
Shanghai International Holding Corp. GmbH (Hamburg) · Eiffestrasse 80 · 20537 Hamburg · Germany
Figure 4
,
M
Figure 2
Figure 5

Publicidad

Tabla de contenido
loading

Tabla de contenido