3) PROGRAMMING
The programming of the various functions of the control unit is carried out by using the LCD display in the receiver
and presetting the desired values in the programming menus described hereunder.
1 - Press the <PG> key, the display shows the first Parameters Menu "PAR".
2 - By using the keys <+> or <->, select the desired Menu (PAR>>LOG>>RADIO>>....).
3 - Press the <PG> key, the display shows the first function available on the Menu.
4 - By using the keys <+> or <->, select the function to be modified.
5 - Press the <PG> key, the currently preset value for the selected function is displayed.
6 - By using the <+> or <-> keys, select the value to be assigned to the function.
7 - Press the <PG> key, "PRG" is displayed which means the programming has been successful.
Note: You can return to the upper menu without making changes if you press the <+> and <-> keys simultaneously
in a Function Menu.
Press PG to select the desired value. OK is shown to confirm a successful programming.
After 60 sec wait, the receiver exits the programming mode and the display switches off.
Each single function, which is available in the control unit, is described in the following tables.
MENU
The operating mode of channel 1 is preset.
The descriptions of the single submenus are shown hereunder:
MCH1
time
cont
MCH2
Same operating modes preset for MCH1.
MCH3
Same operating modes preset for MCH1.
MCH4
Same operating modes preset for MCH1.
Allows to associate to the input 1 one of the output channel, select a value among the following:
in1
OFF-CH1-CH2-CH3-CH4 (default CH1)
Allows to associate to the input 2 one of the output channel, select a value among the following:
In2
OFF-CH1-CH2-CH3-CH4 (default CH2)
MENU
With this function enabled, channel 1 switches only if the corresponding key is pressed for
longer than 3 seconds.
safe
This function is useful specially to control alarm installations or in cases when accidental acti-
vation is to be averted. The default function is preset on OFF.
Allows to set the type of contact to be used for the input 1, select a value between N.O.
In1
(default) N.C.
N.O.: normally open contact N.C.: normally close contact
Allows to set the type of contact to be used for the input 2, select a value between N.O.
In2
(default) N.C.
N.O.: normally open contact N.C.: normally close contact
10
Monostable. The relay activates for 1 sec when the corresponding key is pressed;
IMp
then the relay returns to its original status.
Bistable. When the associated key in the transmitter is pressed, the relay activates.
TG
It remains in its new status until the key is pressed again.
Timed. The switching time of the relay can be set between 1 second and 10 minutes.
By using the <+> and <-> keys, select the desired time. The presettable values are:
from 1 to 10s with 1s steps
from 30s to 300s with 30s steps
from 300s to 600s with 60s steps.
The relay switches each time the corresponding key in the transmitter is pressed
and returns to its original status after its realise.
3.1) PARAMETER
FUNCTION
3.2) LOGICS
FUNCTION