Self-Diagnosis

Display
E0
EC
The sensor for the coin tray is soiled
E1
E8
The respective counting sensor is soiled
-
If there is no improvement after cleaning, refer to Chapter GUARANTEE and call the service number.

Technical specifications

Model
Infeed funnel
Counting speed
Power supply
Power consumption
Permissible ambient temperature
Dimensions
Weight
Switch the machine off prior to cleaning.
Clean off dust with a soft, clean brush or a soft, lint-free
cloth.
Clean the sensors after each use.
10
Cause
The sensor is soiled or damaged.
or damaged.
or damaged.
CC 202
300 - 500 coins
Approx. 215 coins/minute
230 V/ 50 Hz
45 W
0 to 40 °C; 30 to 80% relative humidity
321 x 321 x 270 mm
4.5 kg
Remove the coins and clean the sensor.
Clean the respective sensor.
Disposal
The adjacent symbol indicates that old electric­
al and electronic apparatus and batteries
must be disposed of separate from normal
household waste, in compliance with legal require­
ments.
Packaging materials must be disposed of according to
local regulations.