Trouble or fault
The breaker doesn't
start.
The service indicator
lights red.
The service indicator
blinks red.
No hammering ac-
tion.
The breaker doesn't
start or cuts out dur-
ing operation.
*2190684*
Printed: 05.02.2019 | Doc-Nr: PUB / 5364012 / 000 / 01
Possible cause
Interruption in the elec-
tric supply.
The generator is in sleep
mode.
The detachable supply
cord is not fitted cor-
rectly.
The tool is faulty or ser-
vicing is due.
The voltage provided by
the electric supply is too
high.
The overheating preven-
tion cut-out has been
activated.
The power tool is too
cold.
The extension cord is
too long or its gauge is
inadequate.
2190684
Action to be taken
▶ Plug in another electric
tool or appliance
and check whether it
works.
▶ Apply a load to
the generator by
connecting a second
power consumer (e.g.
worklight). Switch the
tool off and then on
again.
▶ Fit the detachable
supply cord to the
power tool correctly.
▶ Have the product
repaired only by Hilti
Service.
▶ Use a different power
outlet. Check the
electric supply.
▶ Allow the tool to cool
down. Clean the
air vents. Running
under no load is still
possible.
▶ Bring the tip of the
accessory tool into
contact with the
working surface,
switch the power
tool on and allow it
to run. If necessary,
repeat the procedure
until the hammering
mechanism begins to
operate.
▶ Use an extension cord
of an approved length
and / or of adequate
gauge.
English