AUX ALCA-HA 18K Manual De Instalación Y Usuario página 94

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8.2.
OUTDOOR UNIT ERROR CODE EXPLANATION
ERROR CODES
C1
C2
C3
C6
C8
H1
DESCRIPTION
Ambient temperature
Defrosting temperature
Discharge temperature
of inverter compressor
Suction pipe
temperature of
Coil Center temperature
DC inverter compressor
high pressure switch
RECOVERY OR
NOT
YES
YES
YES
YES
YES
YES
94
PROBLEM POSSIBLE
REASONS
Temperature sensor
failure or test
temperature exceed
limit
Sensor connection is
incorrect
Outdoor unit PCB failure
Temperature sensor
failure or test
temperature exceed
limit
Sensor connection is
incorrect
Outdoor unit PCB failure
Temperature sensor
failure or test
temperature exceed
límit
Sensor connection is
incorrect
Outdoor unit PCB failure
Temperature sensor
failure or test
temperature exceed
limit
Sensor connection is
incorrect
Outdoor unit PCB failure
Temperature sensor
failure or test
temperature exceed
limit
Sensor connection is
incorrect
Outdoor unit PCB failure
System pressure
exceed high pressure
switch limit
High pressure switch
failure
Instantaneous power-off
Stop valve closed
Outdoor unit fan stop or
air outlet block
In heating mode indoor
unit fan stop or EXV
block

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Alca-ha 24kAlca-ha 36kAlca-ha 42kAlca-ha 48kAlca-ha 60k

Tabla de contenido