2. Para obtener una lista de fallos del sistema, escriba:
faultmgmtsp> fmadm faulty
----------------- ------------------------------------- -------------- --------
Time
----------------- ------------------------------------- -------------- --------
2010-09-03/20:46:23 fa4a2f86-5156-4243-8e88-d6516db12970 SPT-8000-DH
Fault class : fault.chassis.voltage.fail
FRU
: /SYS/MB
(Part Number: 541-4197-04)
(Serial Number: 1005LCB-1025D40059)
Description : A chassis voltage supply is operating outside of the
allowable range.
Response
: The system will be powered off.
required LED will be illuminated.
Impact
: The system is not usable until repaired.
the system to be powered on until repaired.
Action
: The administrator should review the ILOM event log for
additional information pertaining to this diagnosis.
refer to the Details section of the Knowledge Article for
additional information.
Nota – Si el servidor detecta la sustitución de la unidad FRU defectuosa, la
reparación no necesita un comando de usuario y el fallo se reparará
automáticamente.
3. Descubra más información sobre un fallo concreto.
Localice el MSG-ID del error (en el ejemplo anterior, SPT-8000-DH) y escriba en la
ventana de búsqueda Search Knowledge Base del sitio
http://support.oracle.com.
4. Para obtener información sobre cómo reparar el error, consulte:
"Reparación de errores (shell de administración de errores de Oracle ILOM)" en la
página
68
Guía de administración de los servidores serie SPARC T4 • Noviembre de 2011