ABB-Welcome
4.3
Programming mode
start
1. Long press "Prog" button for 3s to
enter programming mode
2. Choose cameras to set by dip switch
V1/V2/V3/V4
3. Assign the address of the camera
interface by
R3
4. Set the working mode by
Mode=1, Camera interface works as an independent outdoor station.
Mode=2, Camera interface works associated with outdoor station.
Mode=3, Camera interface works associated with guard unit.
Mode=4, Camera interface works associated with indoor station
5. Short-press "Prog" button to save current setting
6. Set the address of the associated
device by these three rotary switches
(R1&R2&R3)
Address=R1*100+R2*10+R3
7. Short-press "Prog" button to save
current setting
8. Long press "Prog" button 3s to exit
programming mode
End
|
R1
R1
R2
Y
continue to
program
N
R3
— 10 —