Setup Procedure; Wiring Plan; Maintenance And Fault Rectification; Remove Interferences - Vega BAR S 16 Instrucción De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4
Fig. 8: Connection to the screw terminals
1
Cable gland
2
Plug housing
3
Plug insert
4
Plug seal
Snap the plug insert into the plug housing and
7
insert the sensor seal
Plug the plug insert with seal to VEGABAR S
8
16 and tighten the screw
The electrical connection is finished.

4.3 Wiring plan

Angle plug connector according to DIN 43650A
+
Fig. 9: Version: Electrical connection "V"
Round plug connector M12x1
-
Fig. 10: Version: Electrical connection "M"
VEGABAR S 16
1
2
3
1
2
3
-
+
5 Set up

5.1 Setup procedure

After mounting and electrical connection, VEGA-
BAR S 16 is ready for operation.
à
Switch on voltage
VEGABAR S 16 delivers a current of 4 ... 20 mA
according to the actual process pressure. Further
settings are not necessary.
6 Maintenance and fault
rectification
6.1 Maintenance
When used as directed in normal operation,
VEGABAR S 16 is completely maintenance free.

6.2 Remove interferences

Causes of malfunction
VEGABAR S 16 offers maximum reliability.
Nevertheless faults can occur during operation.
These may be caused by the following, e.g.:
Sensor
l
Process
l
Supply
l
Signal processing
l
Fault clearance
The first measure to be taken is to check the output
signal. In many cases, the causes can be
determined this way and the faults rectified.
24 hour service hotline
However, should these measures not be success-
ful, call the VEGA service hotline in urgent cases
under the phone no. +49 1805 858550.
The hotline is available to you 7 days a week
round-the-clock. Since we offer this service world-
wide, the support is only available in the English
language. The service is free of charge, only the
standard telephone costs will be charged.
Set up
17

Publicidad

Tabla de contenido
loading

Tabla de contenido