Start Reference Check –
Before starting some sensitive pipe work, an
additional Reference Check can be started manually.
Press and release the M button at the standard display and select Reference Check
using the (+)/(-) and left/right buttons.
Press/release button M  escape/return to the standard display.
Pressing and releasing E button starts the Reference Check considering the current
temperature inside the housing. While the unit checks the correct 0% reference the
beam flashes once a second simultaneously with a thermometer symbol at the display.
Standby Mode –
activating/deactivating the Standby Mode.
Press and release the M button at the standard display and select Standby using the
(+)/(-) and left/right buttons.
www.kreitel-vermessungsgeraete.de
Press/release M button  escape/return to the standard display.
Pressing and releasing E button activates the Standby mode.
The self-leveling will be stopped and the beam will be turned off while the Line alert is still
active. The display shows the Standby symbol.
To deactivate Standby mode and restore full operation of the laser, press and release
E button again.