Electrical Safety:
If required by the National Electrical Code (or Canadian
Electrical Code), this appliance must be installed on a
separate branch circuit.
For appliances equipped with a cord and plug, do not cut or
remove the ground prong. It must be plugged into a
matching grounding type receptacle to avoid electrical
shock. If there is any doubt as to whether the wall
receptacle is properly grounded, the customer should have
it checked by a qualified electrician.
Installer - show the owner the location of the circuit breaker
or fuse. Mark it for easy reference.
Important - Save these instructions for the local electrical
inspector's use.
Refer to data plate for more information. See "Product Data
Plate" under "Service" for data plate location.
WARNING
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is
to be provided, the risk can be reduced by installing a hood
that projects horizontally a minimum of 5 inches beyond
the bottom of the cabinet.
Verify that cabinets above the cooktop are a maximum of
13" (330 mm) deep.
Important Safety Instructions
Gas Safety
Install a gas shutoff valve near the appliance. It must be
easily accessible in an emergency.
Leak testing must be conducted by the installer according
to the instructions in this manual.
Installer - show the owner where the gas shut-off valve is
located.
The minimum supply pressure must be 1" water column
above the manifold pressure printed on the data plate:
The maximum supply pressure must not exceed 14.0
inches water column (34.9Millibars).
Propane Safety
Important note for LP users: The appliance is
shipped from the factory for use with natural gas. It
must be converted for use with propane. A qualified
technician or installer must do the conversion.
The propane gas tank must be equipped with its own high
pressure regulator. In addition, the regulator supplied with
this unit must also be used.
English •
3