Cabinet Requirements; Install Ventilation; Required Clearance - Bosch HDI8054 Serie Manual De Instalación

Ocultar thumbs Ver también para HDI8054 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Cabinet Requirements

This unit is designed for installation near adjacent walls and
projecting surfaces constructed of combustible materials.
Prepare the countertop and cabinets.
Allow a minimum of 30" (76.2 cm) between cabinets
where range is to be installed. No side clearance is
required in the U.S. (In Canada, 12 mm clearance is
required from range sidewalls to cabinets). Height is set by
adjusting the range legs (see later section, "Complete the
installation".
.
Note: The slide-in range can also replace a
freestanding range. In this case, verify that the opening is
at least 30" (76.2 cm).

Install Ventilation

Bosch strongly recommends the installation of a ventilation
hood above this range. For most kitchens a certified hood
rating of not less than 300 CFM is recommended. The
range hood must be installed according to instrutions
furnished with the hood.

Required Clearance

These instructions were determined using standard
American cabinets. Standard base cabinets measure 36"
(91.4 cm) high x 24" (61 cm) deep. Cabinets over the
cooking surface and cabinets adjacent to those over the
cooking surface measure 13" (33 cm) deep from backwall.
If nonstandard cabinets are used, care should be taken to
alter dimensions accordingly.
9 WARNING
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If cabi-
net storage is to be provided, the risk can be redu-
ced by installing a hood that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the
cabinet.
From cooktop to materials above: There must be a
minimum clearance of 36" (91.4 mm) between the top of
the cooking surface and the bottom of an unprotected wood
or metal cabinet. The minimum clearance from the top of
the cooking surface and a vent hood or OTR microwave
hood is 30 inches (72.2 cm).
24" (61 cm) is acceptable when the bottom of the wood or
metal cabinet is protected by (a) not less than 1/4" (6.4
mm) of flame-retardant material which must be covered
with (b) not less than No. 28 MSG sheet metal, 0.015" (0.4
mm) stainless steel' or 0.024" (0.6 mm) aluminum or
copper.
No clearance is required from unit walls to adjacent vertical
combustible walls on rear, right or left.
Clearance from range top to adjacent vertical walls must be
at least 4" (10.2 cm).
Note: Some cabinet finishes cannot survive the
temperatures allowed by safety standards, particularly self-
cleaning ovens; the cabinets may discolor or stain. This is
most noticeable with laminated cabinets.
English 8