2 2 . . T T e e c c h h n n i i c c a a l l D D a a t t a a
2 2 . . 1 1 M M i i s s c c e e l l l l a a n n e e o o u u s s D D a a t t a a
Display
Display range
Out of Range Indication
Data storage
Test voltages
EMC
2 2 . . 2 2 E E l l e e c c t t r r i i c c a a l l D D a a t t a a
2 2 . . 2 2 . . 1 1 P P o o w w e e r r s s u u p p p p l l y y
AC power supply
DC power supply
Mains Hum Filter
2 2 . . 2 2 . . 2 2 I I n n p p u u t t s s
M M e e a a s s u u r r e e m m e e n n t t r r a a n n g g e e s s
Current input (DC)
Ranges
Resolution
Voltage drop
Max. current
Voltage input(DC)
Ranges
Resolution
Input resitance
Max. voltage
A/D converter
Measuring speed
Linearity
Zero calibration
Temperature drift
www.kuebler.com
5 digit red LED
14.2 mm high
–19999 ... 99999, with leading zeros suppression
Under-range uuuuu / Over-range ooooo
EEPROM, 1 Million storage cycles or 10 Years
EN 61010 Part 1 ; overvoltage category 2, level 2
Interference emissions EN 50081-2 / EN 55011 Class B
Interference resistance EN 61000-6-2
90 ... 260 V AC/max. 6 VA
external fuse 100 mA/T
10 ... 30 V DC, max. 2 W,
galvanically isolated with inverse polarity protection
external fuse 250 mA/T
digital filter 50 Hz or 60 Hz, programmable
0 ... 20 mA, 4 ... 20 mA
2 µA
max. 2 V bei 20 mA
50 mA
0 ... 10 V, 2 ... 10 V, ±10 V
1 mV
> 2 MΩ
± 30 V
Dual-Slope
approx. 2 measurements/s
< 0,1% ±1 Digit for the whole measuring range at an
ambient temperature of 20°C
automatic
100 ppm/K
Page 5