Description of the terminals and wirings.
Terminal
1-3
PED
2-3
START
3-4
STOP
5-7
PHOTO
6-7
PH.OP.
7-8
While opening it stops and reverses for 10cm. While closing it
Costa
9-10
11-12
LOCK
13-14
FLASH
15-16
RX Vdc
17-18
M1
19-20
M2
21-22
OUT TRASF.
Wire it to the 24Vac output of the toroidal transformer.
27-28
BATTERY
33-34
P.S.: This control panel is delivered with all N.C. outputs wired (stop, safety edge,
photocells, photocells open). If you want to use one of those outputs, cut the wire
and do the connection accordingly.
Input Pedestrian (N.O. contact); It opens only the leaf of M1.
Input Start (N.O. contact); step by step feature (open-stop-close).
Input Stop (N.C. contact) it always stops the motors. If the
contact is used during the pause, it cancels the automatic shutting.
Input photocells (N.C. contact) working only when gate is
closing (it stops and re-opens).
Input photocells working when gates is opening/closing
(N.C. contact). While opening the gate stops and then re-start;
while closing the gate stops and reverses.
Input safety edge (N.C. contact) working both in opening/closing.
stops and reverses completely.
Output 24 Vdc for photocells power supply
(9 negative, 10 positive).
Output 24 Vdc Dip 2 SW2 OFF Electro-lock -
Dip 2 SW2 ON Indicator of gate movement
(11 negative, 12 positive).
Output 24Vdc for the flashing light (13 negative, 14 positive).
Out put 24 Vdc for accessories (15 positive, 16 negative).
Output 24Vdc for Motor 1 (max 3A).
Output 24Vdc for Motor 2 (max 3A).
Control panel power supply 24 Vac.
Back up battery input 24V (27 positive, 28 negative).
Input antenna for onboard receiver (33 coaxial wire, 34 shield).
Description