Manual setting of the stroke using a remote control.
Ÿ Store the remote control to the START (see page 5).
Ÿ Close the gate and press once both buttons PROGR. and LAVORO; led DL6
starts flashing quickly.
Ÿ Hereinafter follow up the setting as reported (see page 6) pressing remote control
button just stored instead of LAVORO button.
Setting of the automatic shutting time.
Ÿ Close the gate and press once button PROGR.; led DL6 starts flashing.
Ÿ Press once the button PAUSA; led DL6 starts flashing quickly, the control panel is
counting the automatic shutting time.
To stop the counting, press again the button PAUSA; led DL6 switches off.
Ÿ
Maximum time to set is 120 seconds.
To disable the automatic shutting:
Ÿ Press once the button PROGR..
Ÿ Press quickly twice (2 times) button PAUSA
How to get separate inputs OPEN-CLOSE.
How to turn START into CLOSE only:
Cut off power supply, keep pressed both buttons PROGR. and PAUSA and give
power back keeping the buttons pressed down; led DL6 flashes to confirm the good
success of the operation, now release the buttons.
How to turn PED into OPEN only:
Cut off power supply, keep pressed both buttons PROGR. , LAVORO and PAUSA
and give power back keeping the buttons pressed down; led DL6 flashes to confirm
the good success of the operation, now release the buttons.
How to go back to START and PED as sequential/standard inputs:
To get START back, cut off power supply, keep pressed both buttons PROGR. and
LAVORO and give power back keeping the buttons pressed down; led DL6 flashes
to confirm the good success of the operation, now release the buttons.
To get PED back, cut off power supply, keep pressed both buttons PROGR. And
LAVORO and give power back keeping the buttons pressed down; led DL6 flashes
to confirm the good success of the operation, now release the buttons.
P.S.: The control panel 207 is delivered from the factory with inputs START and
PED as sequential/standard inputs
Additional important information.
Ÿ This control panel con work with or without back up battery. In any case, it uploads and keeps
leaded the back up battery at the same time; approx. 24h are necessary to re-charge the battery
for completely. In case the control panel works only with the back up battery, the photocells
start working only in presence of a START signal; moreover, if a flashing light or a door indicator
are wired on the panel, the frequency of the blinks will slow down to save energy.
If the back up battery has almost run out, the control panel remains powered but when the bat-
tery runs out completely, the panel doesn't accept the START signal; the panel needs 140 mA
as normal working that is equivalent to 50 hours working with a back up battery of 7Ah and in
Stand-By 38 mA that is equivalent to 184 hours with a back up battery of 7Ah.
Ÿ This control panel is provided with an anti crashing system that recognises the obstacles. This
feature can be adjusted by the Trimmer AMP. When the gate meets an obstacle while opening,
it stops and reverses the stroke for about 1 sec. and after 30 sec. it closes automatically. When
the gate meets an obstacle while closing, it stops and re-open completely.
In case the automatic shutting is enable and the gate hits an obstacle, the control panel will try
to close the gate for max. 3 times then the gate will remain open, waiting for a START signal in
order to close.
.