Installation

Assembly

10.2 Assembly
10.2.1 Opening the appliance
10.2.2 Removing the back panel
Press the two locking hooks on the r.h. and l.h. side and re-
move the lower part towards the front.
10.2.3 Securing the mounting bracket
Mark out the holes for drilling using the installation tem-
plate. If the appliance is to be installed with water connec-
tions for finished walls, the fixing hole in the lower part of
the template must also be marked out.
Drill the holes and secure the mounting bracket with
two screws and two rawl plugs. The screws and rawl plugs
are not part of the standard delivery.
10.2.4 Preparing the power cable
160
30
Prepare the power cable.
Use the plastic cap as an installation aid..
24
| DHB-E SLi | A electronic
10.2.5 Securing the twin nipples
10.2.6 Preparing the water connection
Secure the tee and cross-piece to the twin nipples with flat
gaskets.
Thoroughly flush the cold water supply line.
Note
Never use the three-way shut-off valve to reduce the flow
rate; it is only designed to shut off a circuit.
1
1 Tee
2 Cross-piece
10.2.7 Fitting the strainer
Fit the sieve provided in the cold water inlet of the appliance.
Note
The sieve must always be fitted for the function of the
appliance to be guaranteed. If an appliance is being re-
placed during installation, ensure that a sieve is available.
2