Operation
Error Recovery Routine
(Continued)
Each of these errors is considered to be
recoverable. The operator has two minutes to
respond to the error condition (except in the
case of "WATER"). During this time, the
computer will turn the signal (buzzer) relay on
and off at the rate of one second on and one
second off to alert the operator to the error
condition. The washer-extractor may be
restarted by pressing the Start key. Pressing
the Start key will restart the cycle step for the
originally programmed time period. "WATER"
will remain displayed until the error is
corrected. The cycle may be aborted by
pressing the Stop key. After aborting the cycle,
the computer will go to the normal stop
routine. If the operator does not respond to the
error condition within the allocated two
minutes, the computer will automatically abort
the cycle.
Note: The "TEMP" alarm can be recovered
only after the temperature falls below the
alarm level.
Certain error conditions are considered to be
non-recoverable:
• If the door opens during a cycle, the
computer will display "DOOR." The
operator must close the door.
Then, after the computer has detected that
the door is closed, it will automatically
abort the cycle and go to the normal stop
routine.
24
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
• "OVERHT" will be displayed when the
computer detects an open or shorted
temperature input circuit or temperatures
are outside of the washer-extractor's
allowable limits. Contact a service
technician.
Manual Mode Control Feature
Manual control is available only while a
preprogrammed cycle is in progress, and if
manual mode is prompted in the WE-6
programming. With the exception of motor
speeds, the reuse tank B drain and tank A and
B fill valves, and the door unlock output, the
WE-6 computer outputs can be operated
manually from the keypad. (In order to ensure
proper sequencing, all motor speeds are always
controlled by the computer.)
Note: When the manual mode control feature
is activated, the operator must supply on/off
commands for the controllable outputs. If an
output is on, it will remain on until turned off
by the operator or until the assigned time for
the manual mode expires. This can be as long
as 9 minutes and 99 seconds.
In normal operation, when the program mode
switch is in the RUN position, only the
operations printed in black on the keys are
accessible to the operator.
F232089