During the manual mode, normal cycle timing
is suspended. When the manual mode is
entered, the operations printed in red on the
keys and mentioned in the following
discussion are activated.
Entering the manual mode during a fill
operation is not recommended. This bypasses
the water-level switch inputs, and the water
must be turned off manually by the operator.
The following procedure must be
accomplished within three seconds in
order to enter the manual mode:
1. Press the Manual key.
2. Then press three number keys to assign a
time in minutes and seconds to the manual
mode. For example, press key 2, key 3,
and key 0 to enter the manual mode for
2 minutes and 30 seconds.
3. Then press the Add Step key.
When the computer receives all these inputs
within the three-second time limit, it will
enter the manual mode for the time assigned.
The computer display will flash between
"MAN230" (reflecting the time chosen in
step 2 of the above procedure) and the current
cycle step display for four seconds.
Note: If "NO MAN" is prompted and the
normal key sequence for manual mode is
entered, the computer will display only the
remaining cycle time.
F232089
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
After four seconds, the display will flash
between "MANUAL" and the current cycle
step display for the remainder of the
assigned time.
Manual mode operation will automatically
end when the assigned time elapses. Normal
program timing will then resume from the
same point in the cycle where the manual
mode was entered. To exit the manual mode
and return to normal program timing before
the assigned time elapses, press the Start key.
All water fill and spray rinse valves, supplies,
heat (if the washer-extractor has reached low
water level), and auxiliary outputs can be
manually controlled. The heat output requires
that only the Heat key be pressed. All other
outputs require that two keys be pressed. For
example, to turn on the cold fill valve, press
the keys Cold and Fill. When an output is on,
pressing the same key or keys which caused it
to energize will turn it off. Thus, to turn off the
cold fill valve, press the keys Cold and Fill
once again.
Operation
25