Tesla J1772 Manual De Instalación página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Note: For top entry installation, the
flexible pre-installed wires that go from
the top entry bracket to the housing are
already terminated and do not need to be
stripped.
4.
Lead the preconnected service wires in
the main housing and connect the
preconnected service wires to the main
terminal block with L1 (or line), L2 (or
neutral), and ground wires going to the
locations shown in the following
illustration.
Caution: Cut each of the wire strands
and insert them fully into each the
terminal block.
Note: To ensure proper operation, neutral
must be connected to the ground bar
inside the circuit breaker box or the main
electrical panel.
5.
Tighten the terminal block to the
recommended torque:
35 in-lb (4.0 N-m) for the terminal
block on the top entry bracket.
33 in-lb (3.8 N-m) for the terminal
block in the main housing.
18 in-lb (2.0 N-m) for the ground
terminal block in the main housing.
6.
Check for miswiring using a multimeter
and verify that there are no shorts before
turning the upstream circuit breaker ON.
Step-by-Step Installation Instructions
Step-by-Step Installation Instructions
17

Publicidad

Tabla de contenido
loading

Tabla de contenido