Starting Of Pw Basic Ph/ Inorganic Chlorine; Recommendations Of Importance - Astralpool POOLWATCH BASIC pH/Cl inor 16647 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ATTENTION:
If the chlorine values after the dosing is superior to the programmed value (see LCD screen ) it means:
The chlorine dispenser pump has a percentage which is too high in the pump flow. Hence, we will have to reduce this percentage.
On the contrary, if we are dosing and we can not reach the programmed value it means that:
The chlorine dispenser pump has a percentage which is too low in the pump flow. We will have to increase this percentage.
8. STARTING OF POOLWATCH BASIC pH / INORGANIC CHLORINE
Once finished with the installation and programming, starting of PW Basic is carried out.
1.- Close sample taking valve (16)
2.- Open water inlet (1) and outlet (17) valves.
3.- Start filtering pump.
4.- Open valve (12) in order to regulate flow in the analysis chamber, letting water circulate inside and adjust its flow to 30 lts/h
(When the flota top (I) emerges over the signal engraved on the front part of the analysis chamber, flow is 30 lts/h).
5.- Switch dispenser pumps on and choose a work proportion that suits swimming pool volume.
ATENTION! It is essential that when we start PW Basic we have water in the following conditions:
- Clear.
- pH value between 7 - 7.8
- Chlorine value between 1-1.5 ppm
- VERY IMPORTANTLY: The water of the swimming pool does not owe of credit presence of cyanuric acid (= 0 ppm Cys).
ELECTION OF WORKING VALUES IN THE POOLWATCH BASIC pH / INORGANIC CHLORINE
It is recommended to have the information about the working margins that the legislation allows respecting Chlorine and pH levels in
the place where it is installed. In the case, we recommend to work with low values (close to the 7.2), hence we have a higher percentage
of free chlorine in form of active disinfectant.
One recommendation is 7.25 (pH) and 1,25 ppm Cl, although you will take the final decision according to the filtering base, quantity of
swimmers, etc.
To have a higher precision in the chlorine reading, it is recommended to make the "ADJUST DPD" in an approximate SP value to the
one we have chosen. If these values are distant one to the other, the Chlorine reading may not be accurate.
We recommend that for the set monitoring you use a photometer PC-Checkit.

9. RECOMMENDATIONS OF IMPORTANCE

When the filtering system works with the help of continuous flocculation, you have to take into account to inject the flocculating after
-
the water connection to the analysis chamber.
Do not put any chemical product in the pool, in the skimmers or in the balance tank. (Example: cartridge or tablets flocculant). these
-
could go directly to the PW Basic and damage seriously their electrodes.
When a filter cleaning is done or when you use a manual bottom cleaner, you have to close the input water valve to the PW Basic
-
(in the collar intake) to avoid the dirt go inside the PW Basic circuit.
A constant flow of 30 litres per hour has to go through the analysis chamber.
-
-
When a water recuperation treatment of the pool is done, we will not let water go inside the analysis chamber. To do this, it is
essential to install a valve in the place where the water of the PW Basic is taken and keep it closed until the recuperation treatment
is finished and the water values in the pool are the normal ones again.
10
Ref: PW Basic-16647-16648-v2-gb-T01

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Poolwatch basic ph/cl inor 16648

Tabla de contenido