4. INSTALMENT PPOLWATCH BASIC pH/INORGANIC CHLORINE
The PW Basic is presented in a PVC panel (60 cm x 60 cm)
1.- Fix the panel to the wall with the separators provided.
2.- Connect the set to a 230 v. ac with a direct earth connection (they do not have to depend on a filter working).
3.- Put the pH electrode (14) in the location area (C) of the analysis chamber (A) .One of the lids of access to the location area must be
unscrewed (C). Take the pH electrode and remove the plastic protections in both extremes, then screw it in the location zone (C)
4.- Connection of pH electrode (14). Take the wire connection (7) and connect it to the pH electrode through the extreme ended in a
thread. The 7 wire is the one on the left. Its connections correspond to the positions 26 and 27 in the grid.
5.- Put the cell of Inorganic Chlorine (15) in the zone (B) of the analysis chamber (A). Unscrew the lid of access to zone (B). This lid has
two parts: a fixing thread and a lid. We take the fixing thread, we put it though the wire extreme (9) of the Inorganic Chlorine cell and we
proceed to wind the cell in its location (B). The connections of the Inorganic Chlorine cell to the grid are the following;
Heald (Blue) 24 (negative), Active (Translucent) 25 (positive)
6.- It is advisable to sep all the protections and lids for a possible future use (for instance, during a long stop, due to reparisons, etc).
7.- The water connection that feeds the water admision to the PW Basic must be as similar as possible to the swimming pool water. This
is why we recommend making an instalment according to what is shown in the graph enclosed. We also recommend filtering part of the
water through the bottom of the pool.
NOTE: In case the swimmimg pool has not been built ywt, ask the department of customer Assistance in ASTRAL POOL.
ATTENTION: It is important that the feeding in PW Basic has a good earth connection, as a security and also to guarantee
its proper functioning. Otherwise, it could provoke instability in the parameters reading. Taking this into account, we advise to give the
PW Basic a proper earth connection.
4. INSTALMENT SCHEME DISINFECTION WITH LIQUID CHLORINE POOLWATCH BASIC pH/INORGANIC CHLORINE
Net water
Compensation tank
NOT TO PLACE THE TANKS OF CHEMICAL PRODUCT UNDER THE DOSING PUMPS.
THE CHEMICAL PRODUCTS MUST BE FAR FROM THE DOSING PUMPS AND OF THE EQUIPMENT POOLWATCH BASIC.
Non stop flocculation unit
Pump recirculation
PE Pipe 8 x10 mm
PE Pipe 8 x10 mm
6
SWIMMINGPOOL
Filter
Exchange temperature
Mín 20 cm
Ref: PW Basic-16647-16648-v2-gb-T01
I n je c t io n P E p ip e s
4 x 6 m m
Tank
Tank pH
sodium
corrector
hypoclorite
Safety
Safety
basin
basin