Installation; How To Install - Kenmore 580.74093 Manual Del Propietário

Acondiclonado de aire a traves de pared
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
We strongly recommend the removal of the
old wall sleeve and the installation of a new
Kenmore Wall Sleeve.
If you decide to keep the existing wall sleeve,
you have to redirect the louvers at the back of the
wall sleeve illustration. The use of pliers is
recommended. If you DO NOT redirect, you run
the risk of poor performance or product failure.
This is not covered under the terms of the
Kenmore warranty.
Pick a location which will allow the conditioned air
to blow into the area you want. Good installation
with special attention to the proper position of the
unit will lessen the chance that service will be
needed.
ITEMS
IN INSTALLATION
HARDWARE
You may not need all parts in the kit. Discard
unused parts
ITEM (inches)
Plastic grille
Vertical insulation strip
Around Insulation Strips
Horizontal Insulation Strip
Support Block
Baffle
Shim
Trim Frame
Washer Screw
Nuts(Plastic)
Grille Rear
263/4 x 161/2
159/16 X 13/8X
13/6
671/8 x 13/6x
25/32
5927/32
X 13/8
X 13/8
237/32 X 13/6 X 13/16
13/4 X 13/8 X 46/16
14 x 41/2x 1/6
1113/16 x 1 x3/4
Qty.
1
1
1
1
1
2
1
2
2
4
4
1
HOW TO INSTALL
D
Identify the existing wall sleeve before installing
the unit from the listed below.
Wall Sleeve Dimensions (inches)
Brand
White-Westinghouse
Frigidaire
Carrier (52F series)
General Electric
/Hotpoint
Whirlpool
Fedders/Emerson
Sears/Kenmore
Emerson/Fedders
Carrier (51S Series)
Friedrich
Width
25-1/2
26
25-7/8
27
25-7/8
26-3/4
25-3/4
27
Height
Depth
15-1/4
16, 17-1/2
or22
15-5/8
16-7/8
17-1/8
16-1/2
or23
16-3/4
16-3/4
or 19-3/4
15-17/32
16-23/32
15-3/4
15
16-7/8
18-5/8
16-3/4
16-3/4
NOTE: All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition
and have a rear grille that securely attaches to
sleeve, or rear flange that serves as a stop for the
Air Conditioner.
_
Remove old air conditioner from existing wall
sleeve.
_-1 Clean the interior of an existing sleeve.
(Do not disturb seals.)
D
Wall sleeve must be securely fastened in wall
before installing the air conditioner.
Use the
nails or screws through sleeve into wall, if
needed. Repaint sleeve if needed.
I_'-'_Prepare the wall sleeve for installation of the
unit. If you plan to use your existing wall sleeve,
and it is not Kenmore, use procedure B or C
below.
Procedure
Brand
Depth(inches)
A
Sears/Kenmore
16-23/32
White-Westinghouse
Frigidaire Carrier
16, 17-1/2
or22
(52F series)
B
General Electric
16-7/8
/Hotpoint
Whirlpool
17-1/8 or 23
Carrier (51S series)
18-5/8
16-3/4
Fedders/Emerson
or 19-3/4
C
Emerson/Fedders
15
Friedrich
16-3/4
_'_ Install new unit into wall sleeve.
CAUTION: The Sleeve must be installed with a
slight downward slope as shown so that water can
drain outside.
LINTEL
(PURCHASED
LOCALLY)
INSIDE_,Io#e
_OUTSIDE
FRONT1/4.
UNIT
Wall Sleeve
2" Minimum
_"Minimum
UNIT
INSTALLATION
INSTALLATION OF SLEEVE
INTO PRE-CAST
CONCRETE
OR MASONRY WALL
SLEEVE
INSTALLATION
FIG. 2
-6-

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

580.74130

Tabla de contenido