Forno DSP-IND-1CG-DCL-30 Manual Del Usuario página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

VI.Counter Installation Instructions:
Connecting to a 3 wires power supply cable electrical system
3. Circuit breaker fuse ratng must be above 40 A , and wire should be 2/8 or 3/8 copper.
4.
Minimum acceptable size of conductors should be no less than 10AWG,copper
only,and no less than167 F .
5. A wire-binding screw or stud used in the wire terminal should be 10 or larger.
Warning!
1.
The electrical power to the cooktop must be shut off while line connectons are
being made.Failure to do so could result in serious injury or death.
2.
An extension cord must not be used with this appliance.Such use may result in
a fire,electrical shock or other personal injury.
3.
To eliminate the risk of bums or fire by reaching over heated surface
units,cabinet storage space located above the surface units should be avoided.
If cabinet storage is to be provided,the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5 inches beyond the bottom of the
cabinets.
lmportant-Save for the local electrical inspector's use.