GYS EXAFEED 4L Manual De Uso página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
3. Setting the inductance :
While pressing the button
guiding the arc. The higher the inductance and the softer the arc with little splatter.
ACCESS TO ADVANCED SETTINGS
Refer to the chapter « menu access » for more details regarding welding parameters.
« SPot », welding duration (in seconds) in Spot / Delay mode.
(1)
« DeLaY », stop duration (in seconds) in Spot / Delay mode
(1)
« PrEgaz », Pre gas, duration (in seconds) of the gas flow between the pressing of the trigger and the start of the wire feeding.
« I Start », starting current (relative scale from -5 to +5), the default value is 0
« Creep Speed », wire creep speed (percentage) before arc ignition
« Hot Start », Activation / deactivation of hotstart settings (On/Off)
(2)
« Creep Voltage », voltage (percentage) at arc ignition
(3)
« HotStart Speed », speed (percentage) during Hotstart
(3)
« HotStart Voltage », voltage (percentage) during Hotstart
(3)
« HotStart time », duration (in seconds) of the Hotstart phase
(3)
« Crater Filler », activation / deactivation of crater filler mode (On/off)
(4)
« Crater Filler Speed », speed (percentage) during crater filling
(5)
« Crater Filler Voltage », voltage (percentage) during crater filling phase
(5)
« downSlope time », duration (in seconds) of the downslope from main welding current to crater filling phase
(5)
« Crater Filler time », duration (seconds) of the crater filling phase
(5)
« burnback », energy required to draw back the wire (relative scale from -5 à +5), the default value is 0
« Post Gaz », duration (in seconds) of the gas flow after the welding stops
: these settings are only available in Spot / Delay mode.
(1)
: the Hotstart settings are only available in Spot / Delay mode.
(2)
: these settings are only visible if H.S. is set to « On ».
(3)
: the CraterFiller settings are only available in Spot / Delay mode.
(4)
: these settings are only visible if C.F. is set to « On ».
(5)
DISPLAY CURRENT/VOLTAGE DURING WELDING
During welding, the machine measures and displays the welding current and voltage. After the weld, the average current and voltage values are
displayed during 30 seconds, as soon as a knob or a button is pressed, the welding parameters are displayed.
Depending on the operation (short-circuit, globular or spray-arc), the average voltage can slightly differ from the setpoint voltage.
SAVE AND LOAD WELDING SETTINGSS
The current settings are automatically saved and loaded at start up.
On top of the current settings, it is also possible to save and load settings per each mode.
There are 50 memory slots
The saved settings include :
- voltage, wire speed and inductance,
- advanced settings.
- 2T / 4T / SPOT DELAY mode
Save new settings :
- Hold buttons
and
- Turn one of the two knobs
- The display indicates a memory set (01 to 50) while blinking.
- Turn the knob to select the memory set in which the desired settings will be saved. Validate by pressing the button
- The settings are saved / the menu exit is instantaneous.
Load existing settings :
- Hold buttons
and
18
, turn the knob
, the index shows a value from -9 à +9. The lower the inductance level, the harder and more
during 3 seconds.
. Validate by pressing the button
during 3 seconds.
EXAFEED 4L
appears, release the buttons.
.
appears, release the buttons.
EN
.

Publicidad

Tabla de contenido
loading

Tabla de contenido