TO CHECK SAFETY VALVE (FIG. 5)
Risk of Bursting. If the safety valve does not
work properly, over-pressurization may occur, causing air
tank rupture or an explosion.
Risk from Flying Objects. Always wear certified
safety equipment: ANSI Z87.1 eye protection (CAN/CSA
Z94.3) with side shields.
Hot surfaces. Risk of burn. Outlet tube, pump
head, and surrounding parts are very hot, do not touch (see the
Hot Surfaces identified in Important Safety Instructions). Allow compressor to
cool prior to servicing.
Before starting compressor, pull the ring on the safety valve (F) to make sure that
the safety valve operates freely. If the valve is stuck or does not operate smoothly,
it must be replaced with the same type of valve.
TO DRAIN TANK (FIG. 5, 6)
Risk of Unsafe Operation. Air tanks contain high pressure air.
Keep face and other body parts away from outlet of drain. Use ANSI Z87.1 eye
protection (CAN/CSA Z94.3) when draining as debris can be kicked up into
face.
Risk from noise. Always wear proper hearing protection during
use. Under some conditions and duration of use, noise from this product may
contribute to hearing loss.
NOTE: All compressed air systems generate condensate that accumulates in any drain
point (e.g., tanks, filter, outlet tubes, dryers). This condensate contains lubricating oil
and/or substances which may be regulated and must be disposed of in accordance
with local, state, and federal laws and regulations.
Risk of Bursting. Water will condense in the air tank. If not
drained, water will corrode and weaken the air tank causing a risk of air tank
rupture.
Risk of Property Damage. Drain water from air tank may contain oil
and rust which can cause stains.
1.
Set the Auto/Off switch (D) to "Off".
2.
Pull the regulator knob (N) out and turn counterclockwise to decrease the outlet
pressure to zero. When the desired pressure is reached push the knob in to
lock the regulator in place.
3.
Remove the air tool or accessory.
4.
Place a suitable container under the drain valves (K) to catch discharge.
5.
Pull ring on safety valve (F , Fig. 5) allowing air to bleed from the tank until tank
pressure is approximately 20 psi. Release safety valve ring.
6.
Drain water from air tank by opening drain valves (K) on bottom of tanks.
7 .
After the water has been drained, close the drain valves. The air compressor
can now be stored.
NOTE: If drain valve is plugged, release all air pressure. The valve can then be
removed, cleaned, then reinstalled.
15 - ENG