Stand Alone Installation; Installation Considerations - Broan GSFH1K Manual De Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. TYPICAL INSTALLATIONS
5.3
S
A
TAND
LONE
(Primarily for homes with no central air mover or equipped with wall furnaces, radiant hot water or electric baseboard heating.)
5.3.1 B
ASEMENT
• Ideal for homes without a central furnace
in the basement. Allows filtration and a
better air circulation throughout the house.
• Easy access to perform the periodic filter
maintenance and servicing.
• Offers an ambient temperature above
freezing (32°F - 0°C).
• The HEPA Filtration model GSFH1K has
no connection to the outside, so all parts
encircled are not required.

INSTALLATION CONSIDERATIONS:

• Installing the unit near an exterior wall will
shorten the length of the insulated ducts
(not necessary for HEPA Filtration only
model GSFH1K).
• If a HEPA Filtration Fresh Air & Heat
Recovery Ventilation model GSHH3K is
installed, a water drain must be close to
collect the run-off.
5.3.2
G
C
ARAGE
LOSET
• Ideal for homes without a central furnace,
or limited space applications, allows filtration
and a better air circulation throughout the
house.
• Easy access to perform the periodic
maintenance (twice a year).
• The HEPA Filtration model GSFH1K has
no connection to outside, so all parts
encircled are not required.
When the ambient temperature for the unit location is below freezing (32°F - 0°C), the unit must run continuously to prevent
condensation.
INSTALLATION CONSIDERATIONS:
• Installing the unit near an exterior wall will shorten the length of the insulated ducts
(not necessary for HEPA Filtration model GSFH1K).
• If a HEPA Filtration Fresh Air & Heat Recovery Ventilation model GSHH3K is installed, a water drain must be close to collect
the run-off.
• All ducts must be insulated.
• For the HEPA Filtration, Fresh Air & Heat Recovery Ventilation (GSHH3K) and the HEPA Filtration, Fresh Air & Energy
Recovery Ventilation (GSEH3K) models only, if the ambient temperature around the unit drops below freezing (32°F - 0°C),
go to Section 6.11 (Low Temperature Applications) for instructions on drain line protection (GSHH3K only) and other cold
environment installation details.
(CONT'D)
I
NSTALLATION
Only for the models GSVH1K,
GSHH3K and GSEH3K that
use fresh outside air.
VH0039
VH0046
CAUTION
- 11 -
Drain required only for the
GSHH3K model.
Only for the models GSVH1K,
GSHH3K and GSEH3K that
use fresh outside air.

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Productos relacionados para Broan GSFH1K

Este manual también es adecuado para:

Gsvh1kGshh3kGseh3k

Tabla de contenido