7. CONTROLS
(CONT'D)
7.5
W
C
ALL
ONTROLLERS
1. Go to the unit. Turn the unit switch knob to OFF position in order to unlock the door. Unlatch the
door and open it. If required, the door can be removed. To do so, remove the stopper (A) located
on the right side of the door hinge. Then, hold the door and hit with your palm its left side. Slide
the door to the right to disengage it from the unit.
2. Using a screwdriver, remove both front plate retaining screws and carefully remove the front
plate of the unit.
3. Using a small rod, pierce a hole through the unit at the end of the wire channel. (See
photo beside). Splice back the end of the cable to access the 4 wires. Remove the insulated
sleeve of each wire ends. Insert the end of the cable through the unit, using the small
hole previously done. From the top right hole of the unit, pull on the wire.
Never use a drill to pierce the hole through the unit, since electrical component
inside the unit may be damaged.
4. In order to access the unit PCB terminals, remove the side door located on the electrical
box and punch out its knockout. Run the cable through the knock-out hole and connect
each wire in their corresponding terminal (YELLOW in "Y'', RED in "R'', GREEN in "G''
and BLACK in "B'').
NOTE: Push forward slightly on the little tabs (1) to ease insertion of each wire.
See photo beside.
5. Reinstall the side door on the electrical box and install the 8'' oval port on the unit.
6. Route the wire through its channel and reinstall the front panel on the unit.
See picture beside.
7. Plug the unit to the wall outlet.
NOTE: When using the wall controller, the main switch on the unit must always be positioned to NORMAL/REMOTE.
C
U
ONNECTION TO THE
CAUTION
(
)
NIT
BOTH MODELS
- 29 -
VD0170
VO0019
VD0088
VE0049
VD0089
A