Functional Description - Milwaukee 48-22-8561 Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GROUNDING
Improperly connecting the ground-
WARNING
ing wire can result in the risk of
electric shock. Check with a qualified electrician
if you are in doubt as to whether the outlet is
properly grounded. Do not modify the plug pro-
vided with the bench. Never remove the ground-
ing prong from the plug. Do not use the bench if
the cord or plug is damaged. If damaged, have it
repaired before use. If the plug will not fit the
outlet, have a proper outlet installed by a qualified
electrician.
Benches with Three Prong Plugs
Benches marked "Grounding Required" have a
power strip with a three wire cord and three prong
grounding plug. The plug must be connected to a
properly grounded outlet (See Figure A). If the
power strip should electrically malfunction or break
down, grounding provides a low resistance path to
carry electricity away from the user,
reducing the risk of electric shock.
The grounding prong in the plug is
connected through the green wire
inside the cord to the grounding sys-
tem in the power strip. The green wire in the cord
must be the only wire connected to the power strip's
grounding system and must never be attached to an
electrically "live" terminal.
Your power strip must be plugged into an appropriate
outlet, properly installed and grounded in accordance
with all codes and ordinances. The plug and outlet
should look like those in Figure A.
SYMBOLOGY
Warning
Read Operator's Manual
Electrical Shock Hazard
Do not open more than one drawer at a
time. Bench may tip, causing injury.
Lock wheels when bench is not
being moved. Unlocked wheels can
allow the bench to move
unexpectedly.
Do not use drawers as steps. Bench
may tip, causing injury.
FPO
Lock all drawers before moving the bench.
Do not step on side shelf. Shelf may
collapse or break. Bench may tip, causing
injury.
Cat. No. ................................................ 48-22-8561
Two-Slide Drawer Capacity .........100 lbs. (45.4 kg)
Four-Slide Drawer Capacity ........200 lbs. (90.7 kg)
Peg Board Capacity.....................200 lbs. (90.7 kg)
Total Capacity ..........................2200 lbs. (997.9 kg)
Recommended Ambient Operating
Temperature ...........0°F to 104°F (-18°C to 40°C)
2
3
4
Fig. A
5
6
1. Peg board
2. Tool hanger
3. Wood work surface
4. Cabinet shelf
5. Cabinet shelf clip
6. Key
7. Swivel caster with
brake
8. Drawer divider
9. Lock
10. Rigid caster
11. Tool organizer
CAUTION
bench. Do not use power tools to assemble
bench. Tighten bolts with hand wrenches.
Phillips
screwdriver
4
SPECIFICATIONS

FUNCTIONAL DESCRIPTION

1
8
9
7
10
12
11
ASSEMBLY
Be sure to follow the assembly in-
structions for the appropriate
Tools Required
Safety
goggles
20
19
18
17
16
15
13
14
12. Drawer slide
13. Bumper
14. Storage shelf
15.Charger mounts
16.Cord storage
bracket
17.Side handle
18.Power strip
19.Locking thumb
screw
20.Peg board bracket
10 mm
13 mm
Wrench
Wrench

Publicidad

Tabla de contenido
loading

Tabla de contenido