NEVER turn water supply off before turning motor off. Serious damage could occur to the pump and/ or
motor.
WARNING! NEVER disconnect high pressure discharge hose from machine while system is pressurized. To
depressurize, turn motor off, turn water supply off and squeeze gun trigger 2-3times.
5. After each use, wipe all surfaces of the pressure washer with a clean, damp cloth.
5. Storage
Do not store pressure washer outdoors.
Do not store pressure washer where it
might freeze.
TIPS FOR EXTENDING THE LIFE
OF YOUR PRESSURE WASHER
1. Never operate unit without water.
2. Pressure washer is not meant to pump hot water. Never connect to hot water supply – this will
significantly reduce life of the pump.
3. Using detergent other than others brand may cause damage to pump components (o-rings, etc.).This also
applies to chemicals such as bleach, dish soap, etc.
4. Never operate unit for more than one (1)minute without spraying water. Resulting heat buildup will
damage pump.
5. Before adjusting nozzle's pressure (high-to-low or low-to-high) release trigger. Failure to do so will reduce
life of o-rings in lance.
ELECTRICAL DIAGRAM
CLEANING AND MAINTANCE
Before any work on the machine itself, pull the mains plug. For safe and proper working, always keep the
machine and ventilation slots clean. In extreme working conditions, conductive dust can accumulate in
the interior of the machine when working with metal. The protective insulation of the machine can be
degraded. The use of a stationary extraction system is recommended in such cases as well as frequently
blowing out the ventilation slots and installing a residual current device (RCD). Please store and handle
the accessory(-ies) carefully. If the machine should fail despite the care taken in manufacturing and testing
procedures, repair should be carried out by an after-sales service centre for Maxpro power tools.
ENVIRONMENT
Do not dispose of electric tools, accessories and packaging together with household waste material -
in observance of European Directive 2002/96/EC on waste of electric and electronic equipment and its
implementation in accordance with national law, electric tools that have reached the end of their life must
be collected separately and returned to an environmentally compatible recycling facility.
TROUBLE SHOOTING
Fault Symptom
Possible Cause
No detergent suction –units with
1. Lance nozzle is not in low pres
tanks
sure
2. High pressure exten-sion hose or
high pressure hose is too long.
3. Injector clogged on pump
No detergent Suction – units with
Detergent applicator is clogged
attachable applicators
Unit begins to smoke
O v e r h e a t e d , o v e r l o a d e d o r
damaged motor
Pressure washer does not start up 1. Unit is pressurized
8
Troubleshooting
1. Slide lance nozzle into low
pressure position
2. Remove high pressure exten-
sion hose or use high pressure hose
shorter than 25 feet.
3. Call the dealer
1. Clean applicator with warm water.
2. Replace applicator
Turn off unit and call the dealer
1. Squeeze trigger on gun
GB
2. Plug is not well connected or
electric socket is faulty
3. Extension cord is too long or
wire size too small
4. Main voltage supply is too low
5. Thermal safety switch has
tripped
Pump does not reach necessary
1. Water inlet filter is clogged
pressure
2. Pump is sucking air from hose
connections
3. Nozzle is worn or not correct
size
4. Unloader is clogged or Worn
5. Valves is clogged or worn
Fluctuating Pressure
1. Pump is sucking in air
2. Clogged nozzle
3. Valves dirty, worn of stuck
4. Water seals worn
Motor stops suddenly
1. Extension cord is too long or
wire size too small
2. Thermal safety switch has
tripped due to overheating
2. Check plug, socket and fuse
3. Remove extension cord
4. Check that main supply voltage
age is adequate
5. Switch off unit and allow motor
to cool down
1. Clean water inlet filter
2. Check that connections and
locking ring are properly tightened
3. Call the dealer
4. Call the dealer
5. Call the dealer
1. Check that hoses and connections
are tight
2. Clean with tip cleaner
3. Call the dealer
4. Call the dealer
1. Remove extension cord
2. Check that main supply voltage
age corresponds to specifications
GB
9