2
General safety notes
2.1 Intended use
The machine is intended for the crimping of flexible wires.
Only the material described below (wires and wire-end fer-
rules) may be processed using the machine. Process-safe
processing can only be guaranteed for Weidmüller wire-
end ferrules.
The processing of other makes may lead to faults and
damage to the machine.
The machine must only be used within the technical limits
described (see section 3.1). Modifications to and recon-
structions of the machine must not be performed.
Intended use also includes paying attention to the docu-
mentation.
2.2 Material that can be processed and
crimp form
Wires
Flexible wires with a cross section of 0,5 – 6,00 mm².
Wire-end ferrules
Weidmüller wire-end ferrules with plastic collar
H0,5/12
H0,5/14
H0,5/16
H0,75/12
H0,75/14
H0,75/16
H1,0/12
H1,0/14
H1,0/16
H1,5/12
H1,5/14
H1,5/16
H2,5/13
H2,5/14
H2,5/16
H4.0/16
Weidmüller twin-wire-end ferrules with plastic collar
H0,5/14 ZH
H0,5/16 ZH
H0,5/18 ZH
H0,75/14 ZH
H0,75/16 ZH
H0,75/18 ZH
H1,0/15 ZH
H1,0/19 ZH
H1,5/16 ZH
H2,5/19 ZH
Weidmüller wire-end ferrules without plastic collar
H0,5/6
H0,5/10
H0,75/6
H0,75/10
H1,0/6
H1,0/10
H1,5/7
H1,5/10
H1,5/12
H2,5/7
H2,5/10
H2,5/12
H4.0/9
H4.0/12
H4.0/15
H6.0/10
H6.0/12
H6.0/15
2639590000/00/11.2018
H0,5/18
H0,75/18
H1,0/18
H1,5/18
H2,5/18
H4.0/18
H4.0/20
H4.0/24
H6.0/20
H6.0/26
H0,75/20 ZH
H0,75/24 ZH
H1,0/25 ZH
H1,5/20 ZH
H1,5/26 ZH
H2,5/24 ZH
H2,5/27 ZH
H1,5/18
H2,5/18
H4.0/18
H6.0/18
A sticker with a correlation list of mm
to this manual.
Crimp form
Quadro (standard)
2.3 Safety equipment
The machine is equipped with the following safety device:
– Mains adapter
This item of safety equipment must not be rendered inef-
fective.
2.4 Personnel
Only trained personnel may operate the machine and per-
form maintenance activities. Training also includes having
fully read the operating instructions.
Repairs may only be performed following con-
sultation with Weidmüller Service and only by
an electrical specialist.
Keep the operating instructions stored so that
they can be inspected by operating personnel
at any time.
All documents can also be downloaded from
the Weidmüller website.
and AWG is attached
2
17