Transporting and setting up the machine

4.1 Installation location

The installation location must meet the following require-
ments:
– Stable foundation with a straight, even surface (for ma-
chine weight, see section 3.1).
– Keep a 30 cm work area free on both sides and in front
of the machine.
– Electricity connections easily accessible close by.
Optimum operating pressure is 5.5 bar
(± 0.5 bar). When operating pressure is less than
5 bar, you will not achieve satisfactory crimping
results. Operating pressures greater than 6 bar
will lead to increased wear on the machine.

4.2 Transporting the machine

► Always wear work shoes with foot protection
when transporting the machine.
► Note the weight of the machine (see section 3.1).
► To move the machine, always lift it using the carry han-
dle.
► To prepare the machine for shipping (e.g. in the event of
servicing), use the transport packaging..

4.3 Unpacking the delivery

► Check the delivery for completeness (for scope of deliv-
ery, see below).
► Store away the transport packaging.
► Ensure that the operating instructions are accessible to
the user at all times.

4.4 Scope of delivery

– Crimping machine
– Mains connection cable (10 A, 250 V)
– Compressed air hose
– Foot switch
– Operating instructions
– Sticker
20

4.5 Establishing connections

► Set up the machine in the intended location.
3
2
4
Figure 4.1 Establishing connections
► First switch on the compressed air hose on the com-
pressed air maintenance unit of the machine (1).
► Only then connect the compressed air hose with the
compressed air source.
► Check the manometer display (2). The operating pres-
sure must be between 5 and 5.5 bar.
► If necessary readjust the operating temperature. To do
this, pull the adjusting screw (3) upwards and turn it
carefully:
– To increase the pressure, turn in a clockwise direction
– To reduce the pressure, turn in an anti-clockwise
direction
► Insert the connector of the foot switch into the connec-
tion socket (4).
► Insert the power cable into the mains connection sock-
et (5) of the machine and connect it to the power supply.