Service Centre - Probuilder 62761 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Spark plug
Clean carbon deposits from the spark plug
after every 100 hours of operation or every 6
months.
Remove the spark plug cap sitting on the
spark plug (19).
bu
Brush away any dust from the area around
the spark plug.
Unscrew the spark plug using a spark plug
socket.
Use a feeler gauge to measure the electrode
gap, which should be 0.7-0.8 mm.
Clean the spark plug with a steel brush or
replace it if necessary.
Retighten the spark plug fully and replace
the spark plug cap.
Other engine parts
Other engine parts may only be serviced,
repaired or adjusted by an authorised
workshop.

Service centre

Note: Please quote the product model
number in connection with all inquiries.
The model number is shown on the front of
this manual and on the product rating plate.
For:
Complaints
Replacements parts
Returns
Guarantee issues
Open weekdays from 07.00 to 17.00
(Fridays until 15.00)
E-mail: service@hpschou.com
GB
41

Publicidad

Tabla de contenido
loading

Tabla de contenido