The left column denotes the current step (1, 2 or 3) while the right represents the value 0-9 being
programmed for this step.
4.1.2 Entering configuration mode
To enter the configuration mode press the button on the back of the panel until the bottom LED in
the left column starts flashing indicating step 1.
Note: The connected Multis or Quattro's switch to 'Inverter only' when the configuration button is
pressed and during configuration mode.
4.1.3 Step 1
The scaling factor is configured in the first step. This parameter is not used in VE.Bus systems so
press the button again to proceed to step 2.
(The left LED column will "display" 2, indicating step 2.)
4.2.4 Step 2 and 3
Because the generator current limit range largely exceeds the 0-9 range we need two steps to
configure the generator current limit. By using 2 steps we can create a value from 0-99. This is
done as follows: In step 2 we program the tens and in step 3 we program the units. For example to
configure a value of 68 we program 6 in step 2 and 8 in step 3.
Important: A range of 0-99A for the generator current limit is not enough to cover all systems.
Therefore the panel multiplies the programmed value by 2 to obtain the generator current limit.
So programming for instance 95 (in steps 2 a 9 and in step 3 a 5) will result in a generator current
limit of 2x95=190A.
Steps to perform:
Determine the required generator current limit.
Divide this value by 2 to obtain the value which must be programmed during step 2 & 3.
Turn the knob until the right LED column "displays" the correct value for step 2.
Press the button to proceed to step 3. (The left LED column will "display" the value 3)
Turn the knob until the right LED column "displays" the correct value for step 3.
Press the button to exit configuration mode and make the new settings effective.
(The panel will function normally displaying the state of the connected system)