ELECTRICAL INSTALLATION

All SYSTEM-POOL baths are designed in accordance with IEC standards. They also undergo exhaustive
technical controls throughout the production process to ensure quality results and optimum safety conditions
for users.
PRELIMINARY ELECTRICAL CONDITIONS
* In accordance with electricity safety standards, the bath must be wired to an all-pole dis-
connection device (see drawing) with a minimum spacing of 3 mm between contacts. The
device must be installed in such a way that it complies with electricity safety regulations for
bathrooms and respects stipulated off-limit and safety areas. The breaker must be suited to
the bath's voltage and current output values. For optimum usage, the bath should be discon-
nected when not in use (see drawing).
* The electrical installation in the bathroom must comply with national regulations.
* Accessible metal parts that are not part of the bath (heating, water, gas installations, etc.) must be connected
to an equipotential grounding contact.
* Any equipment or devices containing electrical components must be positioned or secured in such a way
that they cannot fall into the bath.
SYSTEM-POOL declines all responsibility if any of the indications in our manuals are not followed.