Heatworks 1X Guía De Instalación Y Manual Del Usuario página 10

Ocultar thumbs Ver también para 1X:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7) Using the supplied
ferrules, crimp your
existing L1 wire to the
extension cable L1.
Crimp your existing
ground to the
extension cable
ground. Crimp
your existing L2 wire
to the short red wire
already installed inside
the MODEL 1X case.
8) Upon completion of
step 7, three ferrules
should be crimped in
place as shown in
Figure 5.4.
9) Insert the crimped
ferrules into the
appropriate lugs of the
MODEL 1X power
connector block for L1,
Ground and L2.
Tighten the lugs
securely.
8
10) One conductor of
the extension cable
must now be
connected to the
bottom right terminal
of the MODEL 1X
controller. Bend this
wire as shown
in Figure 5.6 to align it
with the terminal.
Figure 5.3
11) Insert the stripped
portion of the wire
under the clamping
plate of the terminal
and tighten securely as
shown in Figure 5.7.
Figure 5.4
12) The final wiring
connections should
look as shown in
Figure 5.8.
Figure 5.5
CAUTION: Breaker must remain off until installation is complete.
Figure 5.6
Figure 5.7
Figure 5.8