The water tray and fi lter will get dirt and peculiar odor, do maintain periodically.
5. Filter sub-assy
Maintenance
once a month or whenever there's
standard
peculiar smell or dirt
Maintenance
press to clean
method
Press to clean it with
water or warm water
(around 40℃ )
● Wash the fi lter with moderate force to avoid
deforming of the fi lter.
● Wipe with soft sponge.
● Never forcedly scrub with brush.
● Wash with clean water thoroughly to avoid
accident or color changed.
● The water tray could be used in wet after
maintenance.
● Dry out the water tray and assemble it when the
unit will not be used for a long time.
When there's peculiar smell or dirt
Press to wash with clean water or neutral abluent of
40℃ for 30~60mins.
● The abluent volume used should be as the
specifi ed.
● The color changed caused by abluent does not
affect the unit operation.
● Wash the fi lter thoroughly after press.
When the scale (white or brown) is hard to
clean
(The humidifying volume will be decreased if the unit is operating
with scale)
Press to wash it with warm water mixed with
Citric acid (around 40℃ ) or clear water for 2h.
Using volume: 20g Citric acid mixed with 3L
water.
Please extend the press time when there's scale.
Wash the fi lter thoroughly after press.
Citric acid could be bought at drug store.
Requirement
● For different environment, the dirt might be
different.
It is advised to maintain when there's peculiar
smell or the humidifying volume decreased.
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
Press to clean
every square of
the fi lter.
17
6.Filter replace method
Service life for
when the unit is operated
replacement
for accumulative 2000 hours
1. Remove fi lter screen
Rotate to left until a "click"
is heard and then stop.
Do not abandon
the frame
Filter screen
Frame (lower)
Slide along the frame (upper) arrow direction, mark
with " △ ", remove the frame (upper) and the fi lter
screen.
(Press to wash the frame with clear/warm water if the frame
cannot be disassembled.)
2. Assemble the new fi lter screen onto the
frame (lower)
Match the bulge of lower frame and fi lter screen hole.
(Incorrect assembly might cause water leakage)
Match and
assemble
Both sides of the fi lter screen are the same.
3.Upper frame and shaft should be
assembled as original sample.
① Match the"
"at upper frame (till a "click" is
heard)
② Insert the shaft and rotate right.
Do not abandon