Steam Generator TD23
Electrical power rating:
Electrical connection:
Electrical connector:
Mains cable:
Fusing:
Water connection:
Steam output connection:
Minimum water pressure:
Maximum steam pressure:
Amounts of steam:
Weight:
Length x width x height:
Steam Generator TD33
Electrical power rating:
Electrical connection:
Electrical connector:
Mains cable:
Fusing:
Water connection:
Steam output connection:
Minimum water pressure:
Maximum steam pressure:
Amounts of steam:
Weight:
Length x width x height:
Prescribed environmental conditions:
The ambient temperatures must be between 0°C and 50°C for operation, storage and transport.
The machine should be placed on flat, stable flooring with the respective weight carrying capacity
(see Technical data).
Interfaces:
Power supply
Electrical: the electrical power supply is fed through a plug (CEE 5 pole), which is led into the front
of a switching cabinet using an approx. 5 m long cable.
Media connection
Water: the water connection is created using the GeKa coupling at the bottom on the back.
Media disposal / removal
Steam: the produced steam is expelled at the upper back and can be transported to where it is
required through the NW 25 coupling and suitable hoses.
Associated documents
Operating manual, Wiring diagram, Declaration of Conformity
Translation of the original operating manual Steam Generator TD
14.11.2017
23,1 kW
3 phase / N / PE 400 V AC 50 Hz
male CEE 5 pole 63 A
approx. 5 m
35 A
GeKa coupling
NW 25
2.5 bar
2.5 bar
35 kg per hour
approx. 75 kg
860 mm x 345 mm x 690 mm
33 kW
3 phase / N / PE 400 V AC 50 Hz
male CEE 5 pole 63 A
approx. 5 m
50 A
GeKa coupling
NW 25
2.5 bar
2.5 bar
50 kg per hour
approx. 100 kg
910 mm x 510 mm x 780 mm
Technical data
Site 35 of 96
English

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Td9Td16Td23Td33

Tabla de contenido