PROBLEM
The Instant Power won't jump
start my car.
The Instant Power won't
power my 12V device.
The battery in the Instant
Power won't hold a charge.
If these solutions do not eliminate the problem, or for more information
about troubleshooting, contact customer service for assistance:
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485.
DO NOT SHIP UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION
(RMA) number from Customer Service at Schumacher Electric Corporation.
Internal battery type ........................................................Sealed, maintenance-free AGM lead-acid
Nominal voltage ...................................................................................................................12V DC
12V DC power output ................................................................................................................ 15A
Male-to-male accessory cable ......................................................................................... 94500109

TROUBLESHOOTING

POSSIBLE CAUSE
Clamps are not making a good
connection to the battery.
Connections are reversed.
The Instant Power's battery
is not charged.
The vehicle's battery is
defective.
The 12V device is not
turned on.
The Instant Power's battery
is not charged.
The 12V device draws more
than 15A or has a short
circuit.
The battery is bad (will not
accept a charge).

BEFORE RETURNING FOR REPAIRS

services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
Monday-Friday 7:00

SPECIFICATIONS

REPLACEMENT PARTS/ACCESSORIES

to 5:00
CST
am
pm
7
REASON/SOLUTION
Check for poor connection to
battery and frame. Make sure
connection points are clean.
Disconnect the Instant Power
and reverse the clamps.
Press the Battery Status button
on the front of the unit. The
LEDs will indicate the status of
charge.
Have the battery checked.
Turn on the 12V device.
Check the battery charge
status by pressing the Battery
Status button.
Disconnect the 12V device.
The internal breaker will
automatically reset after a
minute or two. Try the 12V
device again.
Have the battery checked.