Example:
The master code and the user codes are in 5 digits.
If you wish to switch to a 4 digits code. Follow the
instruction as indicated in setting the Code Length.
When the master code is modified in 4-digits code
then all the user codes become as well 4-digits code.
E.g.: When the master code length is changed
to
smaller
code
length
of the old code is removed, Mater code 1 2 3 6 9,
in 5-digits code, becomes 2 3 6 9, in 4 digits code.
But when the code length is changed to a longer
code then you must add 0 in front of the old code
D. Changing the master code
1. Enter the master code twice:
(1 2 3 4 5 default value master code).
- 2 beeps are emitted to confirm entry
in programming mode.(Orange LED lights ON).
2. Press
*
4 to modify the master code:
- One beep is emitted.
- Enter the new master code in 4, 5 or 6 digits.
- One beep is emitted to confirm that the master
code is programmed.
3. Press # to exit from the programming mode:
2 beeps are emitted to confirm that the keypad
is in stand-by operating mode (Orange LED lights OFF).
E. Adding, changing or deleting
a user code
Relay output 1
Group 1: From user location 00 to user location 24,
Relay output 2
Group 2: From user location 25 to user location 49.
1. Enter the master code twice
(1 2 3 4 5 default value master code):
2 beeps are emitted to confirm entry
in programming mode. (Orange LED lights ON).
To program codes:
Master code
2. To add a user code, enter the user
location (from 00 to 49):
If the user location is free 1 beep is emitted,
enter the User code in 4, 5 or 6 digits
(according to the code length setup).
then
the
first
(X2) >
2 beeps
3. To Change a User code enter the user location.
- 4 beeps are emitted to indicate that user
location is already programmed.
- Enter a new user code.
- A beep is emitted to confirm the new user code.
4. To delete a User code enter the user location.
digit
- 4 beeps are emitted.
- Enter 0 0 0 0 0 0 in 6-digits length code,
0 0 0 0 0 in 5-digits length code
or 0 0 0 0 in 4-digits length code.
- A beep is emitted to confirm the new user code.
NOTE: If the Pin code is already programmed or is
identical to the master code, then 4 beeps are emitted.
Press # to exit from the programming mode.
2 beeps are emitted to confirm that the keypad
is in stand-by operating mode (Orange LED lights OFF).
F. Time outputs
This section allows to program the Relay
activation time.
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry in
programming mode. (Orange LED lights ON).
2. Press
*
0 to program the key-in keypad time.
- 1 beep is emitted.
- Enter the time in 10th of second.
E.g.: 10 for 10 seconds up to 99 for 99 s.
- One beep is emitted to validate the time.
3. Press
*
1 to program relay 1 output time
(door release time).
- 1 beep is emitted.
- For a latched output enter the time in seconds.
Ex : 01 for 1 second up to 99 for 99 seconds.
- Press 00 for a toggled output.
- One beep is emitted to validate the time.
4. Press
*
2 to program relay 2 output time
(door release time).
- 1 beep is emitted.
- For a latched output enter the time in seconds
E.g.: 01 for 1 second up to 99 for 99 seconds.
- Press 00 for a toggled output.
- One beep is emitted to validate the time
5. Press # to exit from programming mode.
2 beeps are emitted to confirm that the keypad is
in stand-by operating mode (Orange LED lights OFF).