Operating Instructions
User - maintenance
Instructions (Continued)
2. A brush or toothpick or something
similar may be used to dislodge the
dried paint from holes and passages.
NEvER USE mETAL OBJECTS
TO CLEAN PRECISELY DRILLED
PASSAGES. DAmAGED PASSAGES
WILL CAUSE ImPROPER
SPRAYING.
3. Remove and check the fluid needle
for excessive wear at the tip and
straightness.
ImPORTANT: If the needle tip is worn
more on one side than the other, either
the needle is bent or the gun body
has been dropped or knocked out-of-
line. There are no adjustments that
can be made to a bent gun body. Test
the needle by rolling on a flat surface.
Replace if necessary.
Troubleshooting Chart
Stop using tool immediately if any of the following problems occur. Serious personal injury
could occur. Any repairs or replacements must be done by a Qualified Service Person or
Authorized Service Center.
Symptom
Right or left
heavy spray
pattern
Top or
bottom
heavy spray
pattern
Split spray
pattern
Center
heavy spray
pattern
Sputtering
spray
4. Check and replace any damaged
o-rings and seals. O-rings and seals
can be wiped clean but not soaked
in solvent.
5. Unscrew packing nuts and replace
the packing ONLY if a leak will not
stop when the nut is tightened (See
Figure 5). Do not over-tighten a
packing nut because this will restrict
movement of the needle.
6. Re-assemble in reverse order of
above and use a non-silicone oil on
moving parts. Apply Vaseline
light grease on threaded joints and
hose connections.
TECHNICAL SERvICE
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual.
Possible Cause(s)
1. Holes in left or right side of the air cap
are plugged
2. Dirt on left or right side of fluid tip
1. Dried material at top or bottom of fluid
tip
2. Loose air cap or dirty seat
3. Air cap plugged
1. Fan pattern open too far
2. Fluid turned in too far
3. Atomization air too high
1. Fan adjustment partially closed
2. Material too thick
3. Atomization pressure too low
1. Material level too low
2. Container tipped too far
3. Loose fluid inlet connection
4. Loose or damaged fluid tip / seat
5. Dry or loose fluid needle packing nut
6. Air vent clogged
TOOL REPAIR
Only qualified personnel should repair
the tool and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently.
STORAGE
1. When not using spray gun,
or
®
2. Spray gun mUST BE well cleaned
Corrective Action
1. Clean. Use only non-metallic pick
2. Clean
1. Clean
2. Clean and tighten
3. Clean. Use only non-metallic pick
1. Partially close the pattern adjustment
2. Increase fluid
3. Reduce atomization air pressure
1. Open fan pattern adjustment
2. Thin to proper viscosity
3. Increase atomization pressure
1. Refill
2. Hold more upright
3. Tighten
4. Adjust or replace
5. Lubricate and or tighten
6. Clear vent hole
6
turn the fluid adjustment knob
counterclockwise to open which
will reduce spring tension on needle
fluid tip.
and lightly lubricated.