Specifications cont.
Function
Range
4.000A
AC Current
10.00A
All AC current ranges are specified 5% to 100% of range
Overload Protection:
10A/600V Fuse
AC Response:
50 to 60Hz
Function
Range
4.000A
DC Current
10.00A
Overload Protection:
10A/600V Fuse
Function
Range
400.0
Resistance
4.000k
40.00k
400.0k
4.000M
40.00M
Input Protection:
600V AC RMS or 600V DC
Function
Range
40.00nF
Capacitance
400.0nF
4.000µF
40.00µF
400.0µF
4000µF
Input Protection:
600V AC RMS or 600V DC
Resolution
Accuracy ±
(% of reading + digits)
1mA
±(2.5% +3 digits)
10mA
Resolution
Accuracy ±
(% of reading + digits)
1mA
±(2.0% +3 digits)
10mA
Resolution
Accuracy ±
(% of reading + digits)
0.1
1
±(1.5% +5 digits)
10
100
1k
±(2.0% +10 digits)
10k
Resolution
Accuracy ±
(% of reading + digits)
±(5.0% +35 digits)
10pF
100pF
0.001µF
±(3.0% +5 digits)
0.01µF
0.1µF
1µF
±(5% +5.0 digits)
19
Specifications cont.
Function
Range
9.999Hz
Frequency
99.99Hz
999.9Hz
9.999kHz
99.99kHz
999.9kHz
9.999MHz
Input Protection:
600V AC RMS or 600V DC
Sensitivity:
>8V RMS
Function
Range
1.0% to 99.9%
Duty Cycle
Input Protection:
600V AC RMS or 600V DC
Pulse Width:
0.1 to 100mS
Frequency Range:
5Hz to 10kHz
Sensitivity:
>8V RMS
Function
Range
0°F to 1400°F
Temperature
-18°C to 760°C
Input Protection:
300V AC RMS or 300V DC
Resolution
Accuracy ±
(% of reading + digits)
0.001Hz
0.01Hz
0.1Hz
±(1.0% +5 digits)
1Hz
10Hz
100Hz
±(1.2% +5 digits)
1kHz
Resolution
Accuracy ±
(% of reading + digits)
0.1%
±(1.2% +2 digits)
Resolution
Accuracy ±
(% of reading + digits)
0.1ºF
±(2.0% +9ºF)
0.1ºC
±(2.0% +5ºC)
20