A mounting frame is supplied with the ceiling assembly.
Follow the steps below to secure the heat pump to the roof.
Refer to Figure 5.
A.
Locate the heat pump mount gasket over the 14" to
15" square opening in the roof.
B.
Install the ceiling assembly mount frame using the
four bolts found with the ceiling assembly.
V. SECURING THE HEAT PUMP TO THE ROOF
C.
Proper tension has been achieved for each bolt when
any portion of each gasket indicating tab has been
pulled down even with the roof. See Figure 5. The
upper unit has now been properly installed with
optimum gasket compression.
FIGURE 5